Using the Command and Response Tables

The command and response tables on the following pages list valid command ASCII codes, the SCP responses to the host, and a description of the command function or the results of executing the command.

The ASCII to hexadecimal conversion table below is for use with the command and response tables.

ASCII to Hex Conversion Table

Space

Symbol Definitions

] = CR/LF (carriage return/line feed\(hex 0D 0A\

}= Soft carriage return (no line feed\E = Escape key

• = Space

X! = Firmware number

NOTES: Unless otherwise indicated, commands are not case sensitive.

Although most of the ASCII commands are not case sensitive, each uppercase and lowercase letter has its own hex code. For example, the hex equivalent for uppercase Q is 51; the code for lowercase q is 71. The hex codes for both versions of the same letter can be used interchangeably unless otherwise stated.

In the SIS command and response tables, only the lowercase version of the command and its hex equivalent are shown.

33SCP 104 and SCP 226 • Remote Communication

Image 39 Contents
User Guide Precautions FCC Class a Notice 安全须知 中文Conventions Used in this Guide NotificationsContents Vi SCP 104 and SCP 226 Contents About the SCP 104 and SCP 226 System Control Panels About this GuideFeatures Application Diagrams ExtronExtron System 5 IP Connection Diagram for an SCP UL Requirements Installation OperationInstalling or Replacing Button Labels Installation OverviewReplacing a Button Label SCP 104 Rear Panel Rear Panel Features and ConnectionsTwo SCPs. For example SCP power and control connectors These two femaleConnecting a Host to the SCP Wiring the RS-232 PortSW12 on Wiring the Power Connector Wiring the Power Connector OptionalSCP 104 to MLC 104 IP Plus Connecting the SCP 104 to the MLC 104 IP PlusSCP 104 to MLC 104 IP Plus with IRCM-DV+ modules SCP 226 to MLC 226 IPIRCM-DV+ SCP 226 to MLC 226 IP with IRCM-DV+ control modulesSCP to system switcher Address 3 Two SCP 226s to system switcher and two control modulesSCP and System 5 IP Button Functions In-wall or in-furniture mounting options Mounting the SCPMounting Options Mounting to an Electrical BoxMounting an SCP 104 in a Two-gang Electrical Box Mounting to a Lectern SCP 226 LFront Panel Features SCP 104 Front Panel Extron SCP 226 L Front Panel Using the IR 402 with an SCP Volume Indicator LEDs ResettingObtaining the Firmware Loader Program Updating the FirmwareDownload Link for Firmware Loader Loading Firmware to the SCPFirmware Loader Add Device Screen Open Window for Firmware Setting Up RS-232 Communication Communications Between the Host and the SCPBaud rate Data bits Parity None Stop Bits Flow Control None Using SIS Commands Error ResponsesSCP-initiated Messages Symbol Definitions Using the Command and Response TablesCommand and Response Table for SIS Commands Command Ascii Command Hex Response Additional DescriptionInformation Requests Volume Relative Function Upload Firmware Reset to Default SettingsSpecial Function SIS Commands Additional Descriptions Command Ascii Command Response ? and Y? ValuesSwitch Responses IRCM/RCM EnablementFront Panel Button LED Control Volume LED ControlSwitch Number Locations Using the Switch and Button TableSwitch Locations on the SCP Front panel switch locationsControl modules switch locations IR 402 switch locationsSwitch Numbering for Control Modules IRCMs and RCMs Switch Button Switch and Button TableModels Part Numbers Part NumbersModels Included PartsRecommended Cables AccessoriesSCP 104 Cutout Template Cutout TemplatesSurface CUT-OUT Area For Furniture Mount SCP 104 AAP Cutout TemplateSCP 226 Cutout Template SCP 226 AAP Cutout Template SCP 226 L Cutout Template For Furniture MountSCP 104 and SCP 226 Reference Information USA, Canada, South America Central America Japan Extron WarrantyExtron Europe Extron India