Conair GB, WSB manual

Page 35

and EMPTY when this key is pressed.

Since the bin, even when empty, weighs about 1300 grams, it is necessary on initial setup of equipment to instruct the controller of the exact tare weight of the empty bin.

Slight drift in the tare or zero weight during day to day operation is normal. All weight calculations automatically compensate for this drift. However, when the bin is empty, if the weight displayed is more than 50 grams above or below zero, then you may wish to reset the electronics to display zero when the bin is empty.

If, when the bin is empty, the weight displayed is greater than 100, or less than -50, (Parameters TH and TL), the dispense cycle will not begin. Instead, the dump valve will repeatedly try to dump any material it thinks is in the bin or will sound the alarm if weight is below -50. If the load cell calibrations have drifted this far, it is absolutely necessary to reset empty bin weight to zero. These minimum and maximum tare weights are set by the TL and TH parameters. See PARAMETERS, TL and TH for more info.

Allow system to be on for at least 5 minutes to allow for warm up of certain components before setting ZERO or FULL weights.

Generally, when zero weight shifts, the full weight reading shifts the same amount. For this reason, resetting the ZERO WT automatically shifts the FULL WT readout by the same amount. Resetting the ZERO weight usually is all that is necessary to also calibrate the FULL weight.

FULL WT.

THIS HAS BEEN

DONE AT THE FACTORY. IT SHOULD NOT BE

(FULL)

NECESSARY

FOR

YOU TO

DO THIS AGAIN.

 

 

ZERO WT. must

be entered before FULL WT. to achieve proper

 

calibration.

The FULL WT. key will

not function until you

 

have set ZERO

WT. as

described above.

 

If you

wish to reset

the controller

for proper full-weight

 

scale display, use any known weight

as close to full bin

 

weight

as

possible.

Do not exceed 9999 grams. Place this

 

weight

in

the

bin and press the FULL WT. key. The display

 

will show

five dashes (FUL-----). Now enter the actual

 

weight

in

grams of the item you are

weighing.

AGAIN, both FULL WT. and ZERO WT. have been set at the factory. A drift of several grams from these settings is normal and should not be of any concern. Recalibration should be considered only if ZERO is more than 20 grams off or FULL WT. is more than 50 grams off. These errors do not prevent proper proportions from being dispensed. ZERO error is always "tared" for proper weighing of each component. FULL scale error will only cause accumulated totals to be off by the degree of this error. The primary function of the AUTOWEIGH BLENDER is to dispense materials in the proper ratios. Because all components are weighed by the

Page 36

Image 35
Contents Gravimetric Blenders Date Manual Number UGB007/1103 Serial numbers Model numbers Part Operation Part Troubleshooting / SoftwarePart Hardware Maintenance Twelve Component SoftwareSlide Valves Check OUT ProcedureSpecial Features Proceed to Safety Hazards NextAdditional MIX Blade Hazard Safety Hazards MIX BladesSafety Features Safety Interlock Switch Proceed to Assembly NextDisclaimers Part I Assembly Page Proceed to Check OUT Procedure Next Wiring ConsiderationsTouch Weigh BIN Very Lightly Procedure What should Happen Plug in ControllerTurn Power on AT this PointPress Dump KEY Press Alarm KEYFacing the Controller Side of the Blender ALL ModelsPage Model Batch WT Weigh BIN Load Cell Grams Dimensions Rating GBMPassword Selecting Correct ModelZero Part II Operation Load Cell CalibrationCAL OFF CALNatural Ratio to Each Other Turning on Outputs Material TypesRegrind Percent of MIX On the Other Hand Additive Percent of ALL NaturalsRegrind Natural SET=Proceed to Rate Calibration Next TypesOperate Proceed to Entering Settings NextRate Calibration YOU Dont have to do this OperThumbwheel Assignments this is Optional Other Natural SettingsSET Entire MIXGB/WSB 240R Selected Models Special InstructionsMicro Pulse GB/WSB GBMAfter Several Days of Proper Operation Power OFFPower on Instructions for Normal OperationNormal Operating Sequence Each Cycle Wait 5 seconds, until display says Press Display will say Eight Character Display LED Lights Strobe Light and Beeper AlarmsAlarm Silence ROM OKMixer Motor Outlet Mixer Motor ON/OFF/TIMED SwitchInternal Fuses Thumbwheel SwitchesKeypad Summary Description Recipe Keypad Automatic Operation ModeKeypad Description of Functions TotalBtch BatchFast Batch CountOperator TAGKeypad Manual Mode Time TimedPage Keypad Program Mode View FLG 1TY 2TY 3TY CTY MIX 1CS 2CS 3CSTRC ParaYLD Ctrl Page Eeprom ExplanationPage Page Page Page Page Page MIX Time ParametersParameter List Brief Explanations Page OFF Designates Material Type Component ParametersPage FLG Parameter List Full ExplanationsJOG KDF, WDF ROV Page Page Dispense Station Configuration Tare Weight Do not Change These STLXTP XCV + XRCTCV + TRC CPL XALXUL MCT MPOLIQ REG = Regrind NAT = Natural ADD = Additive OFF =Not Used Page Page Page Page Page Page ROC ROV RHL FUL Parameter Default Settings Twelve SoftwareFLG MIX JOG FCV DTI KDF WDF BER3TY 3CS 3AL 3XT 3SE 3WT 1TY = OFF 1CS 1AL 1XT 1SE1MI 1NC 1PT 1RP 1RD 1LA 1POChanging Parameters Rate GR/TIME Prnt OFFPrnt Final DISP,%Final DISP,% What to Check for Page Page Page Calibrate Comp Special TestsTime Comp Last Printed Material Usage InformationPARAMETER, PRT Date Time CurrentPart IV Troubleshooting What to do Typical Problems Page Normal Operating Sequence Material Runs OUT Verifying Load Cell Function CNT Load Cell RAW Signal ReadoutCNT OFF Results to Expect Load Cell Weigh BIN TestCore Dump Clear RoutineClear ALL Restart Internal MIX Motor Level SensorWeigh BIN Dump Valve MIX Problems Page Full Recalibration of Load CellsWeigh Bins Blender Preventive MaintenanceDispense Gates Load CellsPage Computer Outputs Wiring Supplement Page Call Appendix A-2 Gravimetric Batch Blenders Autoweigh GBM Series Models SpecificationsTOP View Front View Side View Gravimetric Batch Blenders AutoWeigh GB100 Series ModelsGravimetric Batch Blenders GB 220 and 420 Models 120V/1 phase/50-60 Hz 240V/1 phase/50-60 HzTOP View Mounting Interface Gravimetric Batch Blenders AutoWeigh GB240 and GB440 Models2124 Gravimetric Batch Blenders AutoWeigh GB900 Series ModelsGB1840 GB1860 Gravimetric Batch Blenders AutoWeigh GB1840 and 1860 ModelsControl Remote Mounted Models WSBM22 WSBM131 WSBM140 Gravimetric Batch Blenders Wsbm Series modelsSide View Front View Side View, R Model Front View, R Model Gravimetric Batch Blenders WSB 100 and 100R Models24.4 Gravimetric Batch Blenders WSB 220 and 420 ModelsWSB442 Gravimetric Batch Blenders WSB 240/440 and 240/440R ModelsGravimetric Batch Blenders WSB 1840, 1850 and 1860 Models Appendix C Appendix C Appendix C Appendix C Appendix C Appendix C Appendix C Appendix C

GB, WSB specifications

The Conair WSB,GB represents a cutting-edge advancement in hair styling technology designed for both professionals and everyday users. Known for its versatility, this styling device merges high-performance with user-friendly characteristics to deliver exceptional results.

One of the standout features of the Conair WSB,GB is its dual voltage capability. This allows users to take it anywhere in the world without worrying about voltage inconsistencies, making it an ideal travel companion. The device's sleek and portable design ensures that it is easy to pack while still being robust enough to handle regular usage.

The WSB,GB incorporates advanced heating technology that ensures rapid heat-up times, allowing users to get to styling quickly. With multiple heat settings, the device caters to various hair types and styles, whether it's coarse, fine, or color-treated hair. This customization is essential for achieving the perfect look while minimizing damage.

Another impressive characteristic of the Conair WSB,GB is its innovative ceramic technology. The ceramic plates distribute heat evenly, reducing hot spots that can lead to hair damage. This feature ensures that styling is not only efficient but also gentle on the hair, promoting a healthy shine and reducing frizz for a polished finish.

The device also boasts a swivel cord, which enhances convenience during use by allowing for free movement without the hassle of tangling. This ergonomic consideration is particularly beneficial for professional hairstylists who may need to maneuver around clients during appointments.

Safety is a crucial aspect of the WSB,GB design. It includes an automatic shut-off feature that turns the device off after a period of inactivity, providing peace of mind for users who might accidentally leave it on when finished.

In summary, the Conair WSB,GB offers various features that cater to the modern user’s needs. With its dual voltage, rapid heating capabilities, ceramic technology, swivel cord, and safety features, it stands out in the crowded hair styling market. Whether you’re a professional stylist or someone looking to elevate your everyday look, the WSB,GB is engineered to meet these demands with excellence.