Conair WSB, GB manual

Page 66

CALIBRATION routine, or simply allowed to adjust automatically as necessary after each cycle.

_WT and _TI are WEIGHT and TIME numbers that, taken together,

indicate a dispense rate for the specified material (WT/TI). This rate is used to calculate an exact time period to dispense the required quantity of material. Both of these numbers are adjusted by the computer logic after each cycle as a means of continuously calibrating the dispense times.

Since rate correction takes place continuously and the battery- backed RAM maintains the correct rate even when power has been turned off, these numbers will only be in error during the first several cycles after a flow rate has been considerably altered.

Should there be a change in auger size, drive motor RPM, or some other change that substantially alters the feed rate of one of the components, the _WT and _TI parameters can be adjusted using the RATE CALIBRATION routine to ensure that the feeders dispense properly right from the beginning without waiting for adjustments to occur.

These numbers are always kept at higher values. The computer will bump both numbers up in value by doubling them both until at least one number exceeds 16,000. The ratio (rate) is still the same but error correction routines work better with higher numbers.

======================================================================

_MI

(Set AUTOMATICALLY by the CALIBRATE routine and also reset

 

10 cycles after every power up)

_MI numbers are set to 80 percent of the amount of material, in grams, that can feed in one second based on normal valid dispense rates. A valid rate is considered the normal dispense rate that occurs under normal conditions with equipment functioning properly. When a rate lower than 80 percent of this actually occurs, it is assumed that an equipment malfunction or loss of material has occurred. Under these circumstances, normal rate correction routines are bypassed.

EXAMPLE: For a 1/2" auger feeder with a 60 RPM motor drive, the normal metering rate is about one gram per revolution or 1 gram per second. Since the _MI number is expressed as tenths of grams,

80 % of this is expressed as:

(_MI 00008)

It is safe to use a _MI number that is too low but NOT safe to use a number too high. Error correction routines will not work when this number is too high.

Power-up always resets _MI to 00001. After 10 cycles have occurred without retries, software will enter a corrected number. An exception to this is when the _AL (Alarm) parameter is set to 0, the MI parameter is left unchanged. RATE CALIBRATION also sets the _MI parameter.

======================================================================

_NC

(Changes itself automatically over time)

_NC is the allowable GRAM error within which NO flow rate

Page 67

Image 66
Contents Gravimetric Blenders Date Manual Number UGB007/1103 Serial numbers Model numbers Twelve Component Software Part Troubleshooting / SoftwarePart Hardware Maintenance Part OperationProceed to Safety Hazards Next Check OUT ProcedureSpecial Features Slide ValvesProceed to Assembly Next Safety Hazards MIX BladesSafety Features Safety Interlock Switch Additional MIX Blade HazardDisclaimers Part I Assembly Page Wiring Considerations Proceed to Check OUT Procedure NextAT this Point Procedure What should Happen Plug in ControllerTurn Power on Touch Weigh BIN Very LightlyALL Models Press Alarm KEYFacing the Controller Side of the Blender Press Dump KEYPage Selecting Correct Model Weigh BIN Load Cell Grams Dimensions Rating GBMPassword Model Batch WTCAL Part II Operation Load Cell CalibrationCAL OFF ZeroTurning on Outputs Material Types Regrind Percent of MIXNatural Ratio to Each Other Natural SET= Additive Percent of ALL NaturalsRegrind On the Other HandTypes Proceed to Rate Calibration NextOper Proceed to Entering Settings NextRate Calibration YOU Dont have to do this OperateEntire MIX Other Natural SettingsSET Thumbwheel Assignments this is OptionalGB/WSB GBM Selected Models Special InstructionsMicro Pulse GB/WSB 240RInstructions for Normal Operation Power OFFPower on After Several Days of Proper OperationNormal Operating Sequence Each Cycle Wait 5 seconds, until display says Press Display will say Eight Character Display ROM OK Strobe Light and Beeper AlarmsAlarm Silence LED LightsMixer Motor ON/OFF/TIMED Switch Mixer Motor OutletThumbwheel Switches Internal FusesKeypad Summary Description Total Keypad Automatic Operation ModeKeypad Description of Functions RecipeBatch BtchBatch Count FastTAG OperatorKeypad Manual Mode Timed TimePage Keypad Program Mode Para FLG 1TY 2TY 3TY CTY MIX 1CS 2CS 3CSTRC ViewYLD Ctrl Page Explanation EepromPage Page Page Page Page Page Parameters Parameter List Brief ExplanationsMIX Time Page Component Parameters OFF Designates Material TypePage Parameter List Full Explanations FLGJOG KDF, WDF ROV Page Page Dispense Station Configuration Tare Weight STL Do not Change TheseXCV + XRC TCV + TRCXTP XAL XULCPL MPO LIQMCT OFF = Not UsedREG = Regrind NAT = Natural ADD = Additive Page Page Page Page Page Page FCV DTI KDF WDF BER Parameter Default Settings Twelve SoftwareFLG MIX JOG ROC ROV RHL FUL1LA 1PO 1TY = OFF 1CS 1AL 1XT 1SE1MI 1NC 1PT 1RP 1RD 3TY 3CS 3AL 3XT 3SE 3WTChanging Parameters Final DISP,% Prnt OFFPrnt Rate GR/TIMEFinal DISP,% What to Check for Page Page Page Special Tests Time CompCalibrate Comp Date Time Current Material Usage InformationPARAMETER, PRT Last PrintedPart IV Troubleshooting What to do Typical Problems Page Normal Operating Sequence Material Runs OUT Verifying Load Cell Function Load Cell RAW Signal Readout CNT OFFCNT Load Cell Weigh BIN Test Results to ExpectClear Routine Clear ALL RestartCore Dump Level Sensor Weigh BIN Dump ValveInternal MIX Motor MIX Problems Page Recalibration of Load Cells FullLoad Cells Blender Preventive MaintenanceDispense Gates Weigh BinsPage Computer Outputs Wiring Supplement Page Call Appendix A-2 Specifications Gravimetric Batch Blenders Autoweigh GBM Series ModelsGravimetric Batch Blenders AutoWeigh GB100 Series Models TOP View Front View Side View120V/1 phase/50-60 Hz 240V/1 phase/50-60 Hz Gravimetric Batch Blenders GB 220 and 420 ModelsGravimetric Batch Blenders AutoWeigh GB240 and GB440 Models TOP View Mounting InterfaceGravimetric Batch Blenders AutoWeigh GB900 Series Models 2124Gravimetric Batch Blenders AutoWeigh GB1840 and 1860 Models GB1840 GB1860Gravimetric Batch Blenders Wsbm Series models Control Remote Mounted Models WSBM22 WSBM131 WSBM140Gravimetric Batch Blenders WSB 100 and 100R Models Side View Front View Side View, R Model Front View, R ModelGravimetric Batch Blenders WSB 220 and 420 Models 24.4Gravimetric Batch Blenders WSB 240/440 and 240/440R Models WSB442Gravimetric Batch Blenders WSB 1840, 1850 and 1860 Models Appendix C Appendix C Appendix C Appendix C Appendix C Appendix C Appendix C Appendix C

GB, WSB specifications

The Conair WSB,GB represents a cutting-edge advancement in hair styling technology designed for both professionals and everyday users. Known for its versatility, this styling device merges high-performance with user-friendly characteristics to deliver exceptional results.

One of the standout features of the Conair WSB,GB is its dual voltage capability. This allows users to take it anywhere in the world without worrying about voltage inconsistencies, making it an ideal travel companion. The device's sleek and portable design ensures that it is easy to pack while still being robust enough to handle regular usage.

The WSB,GB incorporates advanced heating technology that ensures rapid heat-up times, allowing users to get to styling quickly. With multiple heat settings, the device caters to various hair types and styles, whether it's coarse, fine, or color-treated hair. This customization is essential for achieving the perfect look while minimizing damage.

Another impressive characteristic of the Conair WSB,GB is its innovative ceramic technology. The ceramic plates distribute heat evenly, reducing hot spots that can lead to hair damage. This feature ensures that styling is not only efficient but also gentle on the hair, promoting a healthy shine and reducing frizz for a polished finish.

The device also boasts a swivel cord, which enhances convenience during use by allowing for free movement without the hassle of tangling. This ergonomic consideration is particularly beneficial for professional hairstylists who may need to maneuver around clients during appointments.

Safety is a crucial aspect of the WSB,GB design. It includes an automatic shut-off feature that turns the device off after a period of inactivity, providing peace of mind for users who might accidentally leave it on when finished.

In summary, the Conair WSB,GB offers various features that cater to the modern user’s needs. With its dual voltage, rapid heating capabilities, ceramic technology, swivel cord, and safety features, it stands out in the crowded hair styling market. Whether you’re a professional stylist or someone looking to elevate your everyday look, the WSB,GB is engineered to meet these demands with excellence.