Bunn LCR-3 service manual Programming the Dispenser

Page 12

PROGRAMMING THE DISPENSER

Press the Right Hidden Switch for 5 sec. to enter the programming menu. Use the Left and Right hidden switches to scroll through the menu screens. Select Exit to leave the programming function and return to normal operations.

NOTE 1: Flashing menu items indicate which selection is active.

NOTE 2: Values shown below are the factory default values for English units.

NOTE 3: Values in [X - X] are the Min. and Max. for that function.

LCD DISPLAY

READY

SELECT FLAVOR

LEFT DISP RATIO

(-) 30:1 (+)

MID DISP RATIO

(-) 30:1 (+)

RIGHT DISP RATIO

(-) 30:1 (+)

LF DISP VOLUME 1

(-) 36.0oz (+)

LF DISP VOLUME 2

(-) 192.0oz (+)

LF DISP VOLUME 3

(-) 384.0oz (+)

MID DISP VOLUME 1

(-) 36.0oz (+)

MID DISP VOLUME 2

(-) 192.0oz (+)

MID DISP VOLUME 3

(-) 384.0oz (+)

RT DISP VOLUME 1

(-) 36.0oz (+)

RT DISP VOLUME 2

(-) 192.0oz (+)

RT DISP VOLUME 3

(-) 384.0oz (+)

ACTION

Hold the RT Hidden Switch for 5 seconds to enter Programming Functions Use the (+) or (-) buttons to adjust the Mix Ratio

Use the (+) or (-) buttons to adjust the Mix Ratio

Use the (+) or (-) buttons to adjust the Mix Ratio

Use the (+) or (-) buttons to adjust the Volume

Use the (+) or (-) buttons to adjust the Volume

Use the (+) or (-) buttons to adjust the Volume

Use the (+) or (-) buttons to adjust the Volume

Use the (+) or (-) buttons to adjust the Volume

Use the (+) or (-) buttons to adjust the Volume

Use the (+) or (-) buttons to adjust the Volume

Use the (+) or (-) buttons to adjust the Volume

Use the (+) or (-) buttons to adjust the Volume

DESCRIPTION

Normal Display for LCR models.

Enter the desired Mix Ratio for the concentrate used in the Left dispenser. [20:1 - 100:1]

Enter the desired Mix Ratio for the concentrate used in the Middle dispenser. [20:1 - 100:1]

Enter the desired Mix Ratio for the concentrate used in the Right dispenser. [20:1 - 100:1]

Set the desired SMALL portion control volume: (0 - 640 oz) or (0 - 18.93L)

Set the desired MEDIUM portion control volume: (0 - 640 oz) or (0 - 18.93L)

Set the desired LARGE portion control volume: (0 - 640 oz) or (0 - 18.93L)

Set the desired SMALL portion control volume: (0 - 640 oz) or (0 - 18.93L)

Set the desired MEDIUM portion control volume: (0 - 640 oz) or (0 - 18.93L)

Set the desired LARGE portion control volume: (0 - 640 oz) or (0 - 18.93L)

Set the desired SMALL portion control volume: (0 - 640 oz) or (0 - 18.93L)

Set the desired MEDIUM portion control volume: (0 - 640 oz) or (0 - 18.93L)

Set the desired LARGE portion control volume: (0 - 640 oz) or (0 - 18.93L)

12

41129 071409

 

Image 12
Contents LCR-3 HV Phone 217 529-6601 FAX 217BUNN-O-MATIC Commercial Product Warranty Contents IntroductionUser Notices Moving PartsElectrical Requirements Field Wiring Terminal Block Diagram Plumbing RequirementsInitial SET-UP Electrical HOOK-UPPlumbing HOOK-UP Leveling the DispenserDrip Tray Installation Operating Controls and Interface Initial Fill & Heat Rinse Alarm Feature Rinse ProcedureAlarm Level Alarm Mode BIB Empty Lockout Feature Brew Temperature Lockout FeatureEnergy Saver Mode Optional 2- Product OperationProgramming the Dispenser Programming BibEMPTY Lockout HRS +Saver Tank Temp No Exit Action LCD Display Actiondescription CAL Left Pump ? Left CAL Middle Pump ? CAL MID Pump VOLCAL HI WTR VOL WTR Start Delay WTR Stop DelayLCD Display Xxoverflow Test Refill ? Exit YES Test Heater ?Loading the Concentrate Priming the Concentrate LinesOperating the Dispenser To Dispense Hot WaterFilling Cambros or Other Large Containers Cleaning & Preventative Maintenance Preventive MaintenanceWeekly Sanitizing Weekly Refrigeration AIR FilterReplacing the Pump Tubing Draining the HOT Water Tank Troubleshooting Possible Cause Troubleshooting ProceduresNo Display TOO LOW HeatingWater Check for BAD ConnectionsScreen Displayed Possible Cause Calibrating the Left Concentrate Pump Dispenser Flow Rate CalibrationField Calibrating the Empty BIB Warning Schematic Wiring Diagram