SERVICE (cont.)
LAMP STARTER and SOCKET
Location:
The lamp starter (6) is located inside the door assy (1) on the top of the door lower panel (5).
Test Procedures:
1.Disconnect the dispenser from the power source.
2.Disconnect the starter leads from the door wiring harness.
3.Remove lamp starter from starter socket.
4.Check for continuity on each lead of the starter socket.
If continuity is present as described the starter socket is operating properly.
If continuity is not present as described replace the the starter socket.
6.Remove starter (6) from starter socket.
7.Check for continuity across the pins on the bottom of the starter (6).
If continuity is present as described , replace the starter.
If continuity is not present as described, starter is operating properly.
Note: If continuity tests are both as described and lamp does not light, replace the starter socket.
Removal and Replacement (Refer to Fig.17):
1.Open dispenser door assy (1)
2.Remove the five
3.Disconnect the leads on the starter socket from the door wiring harness.
4.Remove lower door panel (5) and starter w/socket
(6) as assembly.
5.Compress the spring tabs on the socket and re- move socket from the door bottom cover (5).
6.Rotate starter 90° and remove from the starter socket.
7.Insert new starter (6) into socket and turn 90° until the pins snap in place.
8.Install new socket by compressing spring tabs on the socket and pushing the socket up through the hole in the lower door panel (5) and releasing spring tabs.
9.Connect the sockets leads to the door wiring harness.
10.Install door lower panel (5) with starter and starter socket on door assy (1) using five
LEVEL CONTROL BOARD AND LEVEL PROBE
P1445 |
FIG. 18 LEVEL CONTROL BOARD AND PROBE |
Location:
The level control board is located behind the lower access panel mounted on the right side of the component bracket.
The Level probe is located on the left center of the tank lid just in front of the overflow tube.
Test Procedure:
1.Disconnect the dispenser from the power source.
2.Remove the violet wire from terminal 1 & pink wire from terminal 4 of the circuit board.
3.Check the voltage across terminals 2 & 3 with a voltmeter. Connect the dispenser to the power source. The indication must be 120 volts ac for two wire 120 volt models, three wire 120/208 volt models, three wire 120/240 volt models and 240 volts ac for two wire 240 volt models.
4.Disconnect the dispenser from the power source.
24 | 28364 011598 |
|