SERVICE (cont.)
RINSE /RUN SWITCH
FIG. 24 RINSE/RUN SWITCH | P1452.40 |
| |
Location: |
|
The rinse/run switch is located on the right side of the whipper motor mounting panel.
Test Procedures:
1.Disconnect the dispenser from the power source.
2.Check for continuity between center terminal and the upper terminal with the switch in the “RUN” lower position. Continuity must not be present with the switch in the “RINSE” upper position.
If continuity is present as described, the switch is operating properly.
If continuity is not present as described, replace the switch.
Removal and Replacement:
1.Open the dispenser door.
2.Remove the facenut securing the run/rinse switch to the whipper motor mounting panel.
3.Remove switch with wires attached from the back side of the whipper motor mounting panel.
4.Disconnect the wires from the switch and dis- card the switch.
5.Refer to Fig. 25 when connecting the wires to the new switch.
6.Install new switch with wires attached through the hole in the whipper motor mounting panel and secure with facenut.
BLK to Main |
Wiring Harness |
BLK from |
Hopper Delay |
Board #4 |
P1456 |
FIG. 25 RINSE/RUN SWITCH TERMINALS |
28 | 28364 011598 |
|