TROUBLESHOOTING (cont.) |
|
PROBLEM | PROBABLE CAUSE |
Dripping from dispense tip | 1. Lime |
| CAUTION - Tank and tank compo- |
| nents should be delimed regularly |
| depending on local water conditions. |
| Excessive mineral |
| less steel surfaces can initiate corro- |
| sive reactions resulting in serious |
| leaks. |
REMEDY
Inspect the tank assembly for exces- sive lime deposits. Delime as re- quired.
2.Dispense solenoid valve (Hot or Cold)
Remove the dispense solenoid valve and clear any obstructions. Rebuild or replace the valve if necessary. See page 29 or 30
Water flows into tank continuously 1. | Level control board and probe | Refer to Service - Level Control Board |
|
| and Probe for testing procedures. |
|
| See page 24 |
2. | Solenoid valve (Inlet) | Refer to Service - Solenoid Valve |
|
| (Inlet) for testing procedures. See |
|
| page 31 |
3. | Overflow Protection Switch | Refer to Service - Overflow Protec- |
|
| tion Switch for testing procedures. |
|
| See page 27 |
Product overflows container | 1. Dispense switch |
| 2. Dispense solenoid valve (Hot or |
| Cold) |
Refer to Service - Dispense Switch for testing procedures. See page 17
Remove the solenoid valve and clear any obstructions. Rebuild or replace the valve if necessary. See page 29 or 30