Bunn JDF-2N Initial SET-UP, Electrical Requirements, Plumbing Requirements, Electrical HOOK-UP

Page 4

INITIAL SET-UP

CAUTION: The dispenser is very heavy! Use care when lifting or moving it. Use at least two people to lift or move the dispenser. Place dispenser on a sturdy counter or shelf able to support at least 150 lbs. (68 kg). The JDF-2 is designed for indoor use only.

Set the dispenser on the counter where it will be used. The JDF-2 requires a minimum of 4 inches (102 mm) of air clearance at the rear and 8 inches (203 mm) of air clearance above the dispenser. Minimal clearance is required between the dispenser sides and the wall or another appliance. For optimum performance, do not let warm air from surrounding machines blow on the JDF-2. Leave some space so the dispenser can be moved for cleaning.

ELECTRICAL REQUIREMENTS

CAUTION: The dispenser must be disconnected from the power source until specified in Electrical Hook-Up. The 120V rated dispensers have an attached cord set and require a 2-wire, grounded, individual branch circuit

rated 120 volts ac, 15 amp, single phase, 60Hz. The mating connector must be a NEMA 5-15R. (Refer to the data plate for exact electrical requirements.)

The 230V rated dispensers have an attached cord that requires an attachment plug cap rated at least 10a, 230V. The attachment plug cap must meet with applicable national/local electrical codes.

ELECTRICAL HOOK-UP

CAUTION: Improper electrical installation will damage electronic components.

1.An electrician must provide electrical service as specified.

2.Using a voltmeter, check the voltage and color coding of each conductor at the electrical source.

3.Connect the dispenser to the power source.

4.If plumbing is to be hooked up later, be sure the dispenser is disconnected from the power source. If plumb- ing has been hooked up, the dispenser is ready for Initial Fill.

PLUMBING REQUIREMENTS

This dispenser must be connected to a COLD WATER system with operating pressure between 20 and 100 psi (138 and 690 kPa). This water source must be capable of producing a minimum flow rate of 3 fluid ounces (88.7 milliliters) per second. A shut off valve should be installed in the line before the dispenser. Install a regula- tor in the line when pressure is greater than 100 psi (690 kPa) to reduce it to 50 psi (345 kPa). Also if the install location experiences pressure fluctuations greater than 20 psi (138kPa). The main water inlet is a 3/8” (9.52 mm) MFL connection.

Additionally, the dispenser’s rinse connection may be connected to a HOT WATER system.

Caution:

MAXIMUM RINSE WATER TEMPERATURE: 170 degrees F (76.6 degrees C)

Use BUNN-O-MATIC tubing, part number 34325.10_ _ (see Illustrated Parts Catalog for complete part num- ber) for hot water connection.

The rinse water operating pressure must be between 20 and 100 psi (138 and 690 kPa). A shut off valve should be installed in the line before the dispenser. Install a regulator in the line when pressure is greater than 100 psi (690 kPa) to reduce it to 50 psi (345 kPa). The rinse water inlet is a 1/4” (6.35 mm) MFL connection.

38310 062205

Image 4
Contents Post Office BOX SPRINGFIELD, Illinois Phone 217 529-6601 FAX 217Contents User Notices Initial SET-UP Electrical RequirementsPlumbing Requirements Electrical HOOK-UPInitial Fill Initial Fill ConnectionLoading PrimingPlumbing Hookup Frozen ConcentratesRefrigeration Switch Refrigeration SwitchSanitize Switch Operating ControlsOperating Controls Press and Hold Models Refer to Fig Dispenser USEPortion Control Models Refer to Fig Daily Parts Washing Cleaning & Preventive MaintenanceWeekly Sanitizing Cleaning Cleaning Monthly Clean Condenser Air Filter Annually Replace Pump TubingAdjustment & Optional Settings Temperature Compensated Refractometer MethodProduct Brix % Mix RatioPer 3-second test Adjustment & Optional Settings Pump Speed Programming Cup Size Programming Portion Control Dispensers OnlyAdjustment & Optional Settings Dispenser Lockout Service LockoutAdjustment & Optional Settings Password ProtectionDispense Fault List Beeper FaultCooling Fault List DBC display FaultDip Switch Function List Refill indicator when concentrate out is detectedControls Off Audio feedback during dispensesFunction List Troubleshooting Problem Probable CauseAccess bath fill valve and top off bath tank All water LEDs flashTroubleshooting ProblemCooling system failure or DBC fault RemedyBottle adapter switch mem- brane Dispense touchpadRefill LED not extinguishing All stations dispense concentrate Main water supply OnlyConcentrate only Problem Probable Cause RemedyWater only Initial fill/setup Cant access programming Programming password featurePassword Nect fittingsFault codes Is powered from the step-downOnce water is set, adjust motor Step-down transformerDifficulty brixing and/or weak bev Pump tubing Erage StationUse of portable water pump Difficulty brixing bag-in-boxCoolant Schematic Diagram Schematic Wiring Diagram Schematic Wiring Diagram Schematic Wiring Diagram JDF-2 Control Panel Circuit Schematic Wiring Diagram JDF-2 Remaining Circuits

JDF-2N specifications

The Bunn JDF-2N is a high-performance coffee brewing system that has gained popularity among coffee enthusiasts and professionals for its innovative features and exceptional brewing capabilities. Designed with user convenience and operational efficiency in mind, this machine is ideal for cafes, restaurants, and various other commercial settings.

One of the standout features of the Bunn JDF-2N is its dual brewing capability. It allows for simultaneous brewing of two distinct coffee batches, accommodating high demand and ensuring that customers receive fresh coffee promptly. This feature is particularly advantageous in busy environments, where quick service is essential to maintain customer satisfaction.

The brewing technology employed in the JDF-2N is designed to optimize extraction and flavor. The machine utilizes a precisely controlled spray head that saturates coffee grounds evenly, allowing for a consistent extraction process. This results in a rich, flavorful coffee that highlights the unique characteristics of each coffee blend. Additionally, the machine is equipped with a large-capacity water reservoir, which guarantees a steady flow of hot water, further enhancing brewing efficiency.

Another notable characteristic of the Bunn JDF-2N is its intuitive digital control panel. This user-friendly interface allows baristas and operators to easily adjust brewing parameters, such as brew temperature and time, tailoring the process to specific coffee types or personal preferences. The programmable features enable users to save their favorite settings, ensuring a consistent coffee experience with every brew.

The build quality of the Bunn JDF-2N is robust, featuring durable stainless steel construction that not only maintains aesthetic appeal but also ensures longevity. The machine is designed with serviceability in mind, allowing for easy access to components for maintenance and repairs.

Moreover, the Bunn JDF-2N is equipped with an innovative hot water faucet, offering immediate access to hot water for tea, soup, or other hot beverages, further enhancing its versatility in a commercial setting.

In summary, the Bunn JDF-2N stands out with its dual brewing functionality, advanced extraction technology, user-friendly interface, and durable construction. It represents an ideal solution for businesses that prioritize quality, efficiency, and customer satisfaction in their coffee offerings. With its array of features and reliable performance, the Bunn JDF-2N is a noteworthy choice for any establishment looking to elevate its coffee service.