TROUBLESHOOTING GUIDE
| IMPINGER CTI | |
|
|
|
SYMPTOM | POSSIBLE CAUSE | EVALUATION |
Oven fan will not run | Incoming Power Supply | Check breakers, reset if required Check power plug |
|
| to be sure it is firmly in the receptacle (if applicable). |
|
| Measure the incoming power, call Power Co., if |
|
| needed |
| Oven Fan Fuses, 5 Amp | Check and/or replace |
| Fuse Holder | Check and/or replace |
| High Limit Thermostat | Check for voltage on both sides of the switch. |
| Control Box (Note: High | Terminals are normally closed. If open, reset and |
| Limit not used in ovens | test oven for proper operation. If thermostat and |
| S/N 3000352) | below.) will not hold and control box temperature is |
|
| not exceeding 140°F (60°C), replace thermostat. |
| Fan Switch | Check continuity between switch terminals. Check |
|
| and insure good wire connections |
| 20 Minute Time Delay | Check for supply voltage at terminal #1 to ground on |
|
| the |
|
| wiring back to power supply. If voltage is present at |
|
| terminal #1, check for supply voltage at terminal #2 to |
|
| ground. If no voltage is present, and the oven fan |
|
| switch is closed, replace the |
| Main Fan Relay | Check continuity of coil. Check for power to relay |
|
| coil. Visually check for contact pull in and contact |
|
| condition. Check for voltage across relay terminals. |
| Fan Motor | Check for opens, shorts, or grounds. WITH POWER |
|
| OFF: Turn fan blade to check for locked rotor. |
| Capacitor | Check for opens, shorts, or grounds. WARNING |
|
| Capacitor has a stored charge, discharge before |
|
| testing. |
No main fan cool | Check for supply voltage at terminal #2 and #3 while | |
down |
| main fan is running. Turn off fan switch and supply |
|
| voltage should continue to be present for 20 min. at |
|
| terminal #2. Replace as needed. |
Main fan continues to | 20 Minute Timer | NOTE: On/Off operation of fan switch will reset timer |
run after cool down |
| to 20 minutes. If timer is accidentally reset, turn off |
|
| main breaker to cancel. If voltage continues to be |
|
| present at terminals 2 and 3 after 20 minutes, verify |
|
| fan switch contacts have opened, replace timer as |
|
| needed. |
No control box | Fan Switch | WITH POWER OFF: Close switch and check for |
cooling |
| continuity across switch terminals. |
| 20 Minute Timer | See "Main Fan Motor will not run." |
| Cooling Fan | Check for voltages at the fan motor, if present, |
|
| replace defective fan motor. |