Belshaw Brothers TG 50 manual Main FAN Relay

Page 51

MAIN FAN RELAY

1.Remove control box cover

2.Remove wires from relay and mark wires for reinstallation.

3.Remove two (2) screws and replace relay.

4.Reassemble in reverse order and check operation.

TIME DELAY RELAY

1.Remove control box cover.

2.Remove wires from relay and mark wires for reinstallation. CAUTION: Resistor should be jumpered across terminals #2 and #3 on some of the early models (SN 3000352 and below) this jumper was installed across terminals #1 and #3 which may cause failure of the timer. Correct when replacing timer.

3.Remove screw and replace relay.

4.Reassemble in reverse order and check operation.

NOTE: Do not overtighten mounting screw as this could damage timer.

RELAY CONTACTOR

1.Remove control box cover.

2.Remove wires and mark wires for reinstallation.

3.Remove four (4) mounting screws and replace contactor.

4.Reassemble in reverse order and check operation.

TRANSFORMER - CONVEYOR

1.Remove control box cover.

2.Disconnect wires from primary and secondary of transformer. Mark wires for reinstallation (#23-blue- 208V connection/#24-red-240V connection).

NOTE: Wire nut one not being used.

3.Remove two (2) mounting screws and replace.

4.Reassemble in reverse order and check operation.

CONVEYOR DRIVE MOTOR

1.Remove conveyor (see Installation and Operations Manual).

2.Remove screw from center of coupling sleeve assemby. and slide coupling assembly off motor shaft.

3.Remove control box cover.

4.Disconnect motor leads and mark wires for reinstallation and conveyor direction.

5.Remove four (4) motor mounting screws and replace motor.

6.Reassemble in reverse order and check operation.

NOTE: Check to insure coupling and conveyor shaft are aligned.

NOTE: Starting with SN 3000481 all conveyor drives will be a closed loop system. The drive motor assembly will include a hall effect sensor board and magnet. No calibration required.

S/N 3000480 and Below--Check calibration of conveyor control board (See

"Conveyor control board

calibration")

 

S/N 3000481 and Above--Attach correct magnet to conveyor motor assembly.

 

November 1999

37

COUNTER TOP IMPINGER

Image 51
Contents Operator’s Manual ThermoglazePage Equipment Record Page Contents Preface Unloading and Uncrating Do not Lift Excessive WeightThermoglaze Description KEY Identification2RVO Electrical Installation3Front view Assembly4Infeed Left hand view Control Panel View Oven Ready Light Operation5Daily TG Cleaning Instructions Cleaning6MN-1716EN Thermoglaze Thermoglaze MN-1716EN MN-1716EN Thermoglaze Thermoglaze MN-1716EN MN-1716EN Thermoglaze Thermoglaze MN-1716EN Cleaning Thermoglaze MN-1716EN MN-1716EN Thermoglaze Thermoglaze MN-1716EN MN-1716EN Thermoglaze Slide the heat shield over the oven Maintenance7 Troubleshooting8 Conveyor will not Move Pump Motor will not RUN Speed control/cook time adjustment Appendix9 TNG-2011. Thermoglaze Assembly TNG-2011. Thermoglaze Assembly TNG-2011. Thermoglaze Assembly TNG-2011. Thermoglaze Assembly TNG-2011. Thermoglaze Assembly Thermoglaze MN-1716EN MN-1716EN Thermoglaze Thermoglaze MN-1716EN MN-1716EN Thermoglaze Thermoglaze MN-1716EN Thermoglaze SK-1258 R5Symptom Possible Cause Evaluation Troubleshooting GuideOven will not heat Conveyor will not run 3000481 & Above Model Series REMOVAL, INSTALLATION, and AdjustmentTHERMOSTAT, Oven Cavity HI-LIMIT Main FAN Relay Assembly of Magnet to Motor Temperature Controlboard Cooling FAN, Control BOX Thermocouple AIR Pump Letter Description General 1300 SeriesGeneral 1300 Series Parts BLOW-UP Control Compartment 1300 Series Control Compartment 1300 Series Blow UP Back 1300 Series Back 1300 Series Blow UP Standard Conveyor 1300 Series Extended Conveyor 1300 Series