Belshaw Brothers TG 50 manual 3000481 & Above

Page 48

Conveyor will not run

Fan Switch

WITH POWER OFF: Check continuity between switch

(S/N 3000481 & Above)

 

terminals. Check and insure good wire connections.

 

Conveyor Control

With the fan switch on, check for supply voltage at the

 

Transformer

primary of the transformer. Check for voltage on the

 

 

secondary side of transformer (24 VAC) at J4 and J5 on

 

 

the conveyor control board. Replace as needed.

 

Speed Adjustment Pot

This is a 50 K ohm potentiometer. WITH POWER OFF:

 

 

Remove the leads from the motor control board at

 

 

terminals P1, P2, P3. With a digital meter, check the

 

 

ohm reading across the red and black leads. This

 

 

reading should be 50K ohms (± 10%) as the pot. is

 

 

rotated from low to high. Place meter leads on red and

 

 

white lead. Rotating the pot. slowly from low to high, the

 

 

meter reading should show an even transition from 0 to

 

 

50 K ohms (±10%). There should be no dead or opens

 

 

spots throughout the rotation of the pot. Check all three

 

 

(3) leads to ground. There should be no continuity to

 

 

ground. If any of the above checks fail, replace the pot.

 

Conveyor Control

Check for 24 VAC input to the control board at terminals

 

Board

J4 and J5. If not present, check wiring back to control

 

 

transformer, if voltage is present at J4 and J5, check the

 

 

VDC output at terminals J2 (+) & J3 (-) (0-18 VDC). If

 

 

24 VAC is present at J4 and J5, but VDC is not present

 

 

at J2(+) & J3(-) replace board.

 

Conveyor Gear Motor

If D.C. voltage is present at J2(+) and J3(-) and the

 

 

motor does not run, first check the mini breaker (.7Amp).

 

 

Check the leads to the motor for evidence of any shorts

 

 

or opens, and each lead to ground. If the motor fails the

 

 

above tests, replace motor.

 

Conveyor

Check for any mechanical misalignment or improper

 

 

adjustment, also check for worn bearings. A conveyor

 

 

belt that is too tight will cause excessive bearing wear

 

 

and sometimes, irregular speed.

Conveyor speed

Power Supply

Check for steady supply voltage to oven. If voltage is

varying or intermittent

 

unsteady, contact Power Company.

 

Transformer

Check for steady AC voltage output from transformer

 

 

and replace as needed.

 

Conveyor Control

Check for steady D.C. voltage output from conveyor

 

 

control. If D.C. voltage output is unsteady, check

 

 

conveyor potentiometer (See Speed Adjustment

 

 

Potentiometer" under Conveyor will not run). If the

 

 

potentiometer checks good, and the D.C. voltage is

 

 

unsteady, replace conveyor control.

 

D.C. Gearmotor

Check motor brushes for excessive arching and/or

 

 

unusual wear. Replace brushes or gearmotor as

 

 

needed

 

Magnet

Check to insure that the magnet (cemented to shaft of

 

 

conveyor drive motor) has not been damaged, or come

 

 

loose from motor shaft. Replace as needed.

 

Hall Effect Sensor

Check for any physical damage to Hall Effect Sensor

 

 

(mounted on conveyor motor). Check all wiring and

 

 

connections or damage. Check all connections for

 

 

tightness or proper location and check all wiring or

 

 

visible damage. Replace as needed.

November 1999

34

COUNTER TOP IMPINGER

Image 48
Contents Thermoglaze Operator’s ManualPage Equipment Record Page Contents Preface Do not Lift Excessive Weight Unloading and UncratingIdentification2 Thermoglaze Description KEYRVO Installation3 ElectricalAssembly4 Front viewInfeed Left hand view Control Panel View Operation5 Oven Ready LightCleaning6 Daily TG Cleaning InstructionsMN-1716EN Thermoglaze Thermoglaze MN-1716EN MN-1716EN Thermoglaze Thermoglaze MN-1716EN MN-1716EN Thermoglaze Thermoglaze MN-1716EN Cleaning Thermoglaze MN-1716EN MN-1716EN Thermoglaze Thermoglaze MN-1716EN MN-1716EN Thermoglaze Slide the heat shield over the oven Maintenance7 Troubleshooting8 Conveyor will not Move Pump Motor will not RUN Speed control/cook time adjustment Appendix9 TNG-2011. Thermoglaze Assembly TNG-2011. Thermoglaze Assembly TNG-2011. Thermoglaze Assembly TNG-2011. Thermoglaze Assembly TNG-2011. Thermoglaze Assembly Thermoglaze MN-1716EN MN-1716EN Thermoglaze Thermoglaze MN-1716EN MN-1716EN Thermoglaze Thermoglaze MN-1716EN SK-1258 R5 ThermoglazeTroubleshooting Guide Symptom Possible Cause EvaluationOven will not heat Conveyor will not run 3000481 & Above REMOVAL, INSTALLATION, and Adjustment Model SeriesTHERMOSTAT, Oven Cavity HI-LIMIT Main FAN Relay Assembly of Magnet to Motor Temperature Controlboard Cooling FAN, Control BOX Thermocouple AIR Pump General 1300 Series Letter DescriptionGeneral 1300 Series Parts BLOW-UP Control Compartment 1300 Series Control Compartment 1300 Series Blow UP Back 1300 Series Back 1300 Series Blow UP Standard Conveyor 1300 Series Extended Conveyor 1300 Series