Belshaw Brothers TG 50 manual Thermocouple

Page 55

THERMOCOUPLE

1.Remove control box cover.

2.Remove six (6) acorn nuts holding motor cover and remove.

3.Remove four (4) acorn nuts holding oven back assembly and remove oven back.

4.Remove thermocouple bulb from wire form in rear of oven cavity.

5.Disconnect and mark wires from temperature control board (red=neg., white=pos.) and remove thermocouple.

6.Reassemble in reverse order and check operation. NOTE: Be certain to replace insulation seal each time oven back is removed.

INFORMATION:

When two wires composed of dissimilar metals are joined together and one of the ends is heated, a continuous current flow is generated. We use an iron constant (Type J) thermocouple. The iron wire increases the number of dissimilar junctions in the circuit.

It is possible to check a thermocouple with a properly calibrated D.C. millivolt meter. At 32°F, the millivolt reading should be 0.00. This can be checked by inserting the thermocouple into an ice bath. The millivolt reading at 72°F should be 1.134.

When using the following chart, the temperature at the terminal connections must be noted. This temperature is called the Junction Temperature.

The following chart lists the thermocouple millivolt readings from 200°F to 600°F.

J U N C T I O N T E M P E R A T U R E

O V E N T E M P E R A T U R E

 

200°F

250°F

300°F

325°F

350°F

400°F

425°F

450°F

500°F

550°F

600°F

90°F

3.26

4.77

6.30

7.06

7.83

9.37

10.14

10.91

12.46

14.00

15.53

88°F

3.32

4.83

6.36

7.12

7.89

9.43

10.20

10.97

12.51

14.05

15.59

86°F

3.37

4.88

6.41

7.17

7.94

9.49

10.26

11.03

12.57

14.11

15.65

84°F

3.43

4.94

6.47

7.23

8.00

9.54

10.31

11.09

12.63

14.19

15.71

82°F

3.49

5.00

6.53

7.29

8.06

9.60

10.37

11.14

12.69

14.23

15.76

80°F

3.55

5.06

6.59

7.35

8.12

9.66

10.43

11.20

12.74

14.28

15.82

78°F

3.60

5.11

6.64

7.40

8.17

9.72

10.49

11.26

12.80

14.34

15.86

76°F

3.66

5.17

6.70

7.46

8.23

9.77

10.55

11.32

12.86

14.40

15.94

75°F

3.69

5.20

6.73

7.49

5.26

9.80

10.57

11.35

12.89

14.43

15.97

74°F

3.72

5.23

6.76

7.52

8.29

9.83

10.60

11.37

12.92

14.46

15.99

72°F

3.78

5.29

6.82

7.58

8.35

9.89

10.66

11.43

12.97

14.51

16.05

70°F

3.83

5.34

6.87

7.63

8.40

9.95

10.72

11.49

13.03

14.57

16.11

68°F

3.89

5.40

6.93

7.69

8.46

10.00

10.78

11.55

13.09

14.63

16.17

66°F

3.95

5.46

6.99

7.75

8.52

10.06

10.83

11.61

13.15

14.69

16.23

64°F

4.01

5.52

7.05

7.81

8.58

10.12

10.89

11.66

13.20

14.74

16.28

62°F

4.06

5.57

7.10

7.86

8.63

10.18

10.95

11.72

13.26

14.80

16.34

60°F

4.12

5.63

7.16

7.92

8.69

10.24

11.01

11.78

13.32

14.86

16.40

November 1999

41

COUNTER TOP IMPINGER

Image 55
Contents Operator’s Manual ThermoglazePage Equipment Record Page Contents Preface Unloading and Uncrating Do not Lift Excessive WeightThermoglaze Description KEY Identification2RVO Electrical Installation3Front view Assembly4Infeed Left hand view Control Panel View Oven Ready Light Operation5Daily TG Cleaning Instructions Cleaning6MN-1716EN Thermoglaze Thermoglaze MN-1716EN MN-1716EN Thermoglaze Thermoglaze MN-1716EN MN-1716EN Thermoglaze Thermoglaze MN-1716EN Cleaning Thermoglaze MN-1716EN MN-1716EN Thermoglaze Thermoglaze MN-1716EN MN-1716EN Thermoglaze Slide the heat shield over the oven Maintenance7 Troubleshooting8 Conveyor will not Move Pump Motor will not RUN Speed control/cook time adjustment Appendix9 TNG-2011. Thermoglaze Assembly TNG-2011. Thermoglaze Assembly TNG-2011. Thermoglaze Assembly TNG-2011. Thermoglaze Assembly TNG-2011. Thermoglaze Assembly Thermoglaze MN-1716EN MN-1716EN Thermoglaze Thermoglaze MN-1716EN MN-1716EN Thermoglaze Thermoglaze MN-1716EN Thermoglaze SK-1258 R5Symptom Possible Cause Evaluation Troubleshooting GuideOven will not heat Conveyor will not run 3000481 & Above Model Series REMOVAL, INSTALLATION, and AdjustmentTHERMOSTAT, Oven Cavity HI-LIMIT Main FAN Relay Assembly of Magnet to Motor Temperature Controlboard Cooling FAN, Control BOX Thermocouple AIR Pump Letter Description General 1300 SeriesGeneral 1300 Series Parts BLOW-UP Control Compartment 1300 Series Control Compartment 1300 Series Blow UP Back 1300 Series Back 1300 Series Blow UP Standard Conveyor 1300 Series Extended Conveyor 1300 Series