CDA RC9321 manual Provision for ventilation

Page 33

Provision for ventilation

The appliance should be installed into a room or space with an air supply in accor- dance with BS 5440-2: 2000.

For rooms with a volume of less than 5 m3 - permanent ventilation of 100 cm2 free area will be required.

For rooms with a volume of between 5 m3 and 10 m3 a permanent ventilation of 50 cm2 free area will be required unless the room has a door which opens directly to the outside air in which case no permanent ventilation is required.

For rooms with a volume greater than 10 m3 - no permanent ventilation is required.

NB. Regardless of room size, all rooms containing the appliance must have direct access to the outside air via an openable window or equivalent.

Where there are other fuel burning appliances in the same room, BS 5440-2: 2000 should be consulted to determine the correct amount of free area ventilation require- ments.

The above requirements allow also for use of a gas oven and grill but if there are other gas burning appliances in the same room, consult a qualified engineer.

33

Image 33
Contents RC9321 Twin Cavity Gas Cooker CDA Contents Assembling the backguard IntroductionGas burners Features and technical dataMinute counter Control panelHow to use the hob burners Hob burnersLighting of the hob burners Burners Pan diameter Choice of burnerCorrect use of triple-ring burner General features How to use the gas oven left ovenOven burner Oven thermostatOven cooking Lighting the oven gas burnerLighting the grill gas burner How to use the gas grill left ovenOven light Use of the grillHow to use the gas oven right oven Lighting the oven gas burner How to use the gas grill right oven Important Warning Use of the rotisserie Rotisserie right ovenOven cooking temperatures Do’s and do not’s Do’s and do not’sFor your safety Important notesOven door guard Cleaning the hob Care and maintenanceFlexible tube Gas tapsChanging the oven light Enamelled partsTriple ring burner BurnersStorage compartment Removal of the inner glass door panelAssembling and remov- ing the side racks Inside of ovenRemoving the oven door Door assemblyLocation For the InstallerAir Vent Fitting the adjustable feet Levelling the cooker Moving the cookerStability bracket Provision for ventilation Important Note Gas installationGas connection Installation to Natural GasLeft gas Right gas Inlet pipe 200 mm 700 mm Injectors replacement of top burners Adjusting of the minimum of the top burnersConversion to Natural Gas or to LPG Table for the choice of the injectors Left Oven Oven burner and grill burner replacement of injectorsRegulation of air supply to oven and grill burners Right Oven Regulation of air supply to oven and grill burners Regulating of the oven minimum Left and Right OvensLubrication of the gas taps For your safety please read the following information Electrical installationFeeder cable section type H05RRF Electrical feeder cable connectionAppliance servicing Limit of Cover GuaranteePage Page RC 9321 .. cookers