Hoshizaki ROX-20TA-U service manual A6 Storage Mode/Hand-washing Mode

Page 20

7)While pushing the Set Button, press the Display Button one time.

8)Check that the Display Window reads “CHE.”, which means the unit is in the check mode.

9)While pushing the Set Button, press the Display Button one more time.

10)Check that the Display Window reads “Nor.”, which means the unit is in the normal mode.

11)Release the Set Button.

12)This is the end of adjustment.

A6: Storage Mode/Hand-washing Mode

1)Follow the steps 1) to 8) in “A1: Cell Lifecycle” to show “A 1” in the Display Window on the Control Panel.

2)Push the Set Button five times to show “A 6” in the Display Window.

3)Push the Flush Button one time. The Display Window will flash the following patterns: HANd --------- With the Remote Controller installed

POOL -------- With the Water Tank installed SFt.H --------- Do not set.

SFt.P --------- Do not set.

Flashing

Flashing

Flashing

Flashing

4)Push the Display Button or Flush Button. The Display Window will flash the other set mode.

5)To determine the set mode, press the Set Button one time. The Display Window will stop flashing and show the set mode, then “A 6” which means completion of the adjustment.

18

U8AA5540012

Image 20
Contents Model ROX-20TA-U Contents General Information Safety Instructions U8AA5540012 Product Information DIMENSIONS/CONNECTIONS Features of Strong Acid Water Principle of Strong Acid Water Generation II. Construction General U8AA5540012 Control Panel Display Panel Control BOX Outlet Valves Option Remote Controller OptionWater Tank Float Switches Option U8AA5540012 Adjustment Procedure A1 Cell LifecycleLighting A2 Amperage A3 VoltageA4 Cell Reverse Time A5 Amperage Accumulation TimeA6 Storage Mode/Hand-washing Mode A7 Cell Running/Reverse Time Reset A8 Initial Flush Cycle TimeA9 Automatic Dispensing Control Functions and Adjustment of Check Items Checking ProcedureLighting Flashing C1 Output Conditions C2 Input ConditionsOperation Flow Chart Set CheckIV. Technical Information Water Circuit Wiring Diagram Performance Data PH and Amperage Service Information MAINTENANCE/INSPECTION Acid Water pH, Alkaline Water pH No Available Chlorine Concentration Acid NoThiosulfuric Acid Titration Cell Replace Lamp NoService Diagnosis Cartridge Filter NoU8AA5540012 U8AA5540012 MINAMIYAKATA, SAKAE, TOYOAKE, Aichi 470-1194 Japan