Hoshizaki ROX-20TA-U Acid Water pH, Alkaline Water pH No, Thiosulfuric Acid Titration

Page 32

[a] Acid Water pH, Alkaline Water pH [No. 1, 2]

Always use the accessory pH test paper or a pH tester on the market to check pH. Carefully read the instructions provided with the test paper or tester, and use it properly.

[b] Available Chlorine Concentration (Acid) [No. 3]

Always use the accessory test paper or the thiosulfuric acid titration specified below to check available chlorine concentration.

Carefully read the instructions provided with the test paper, and use it properly.

If the available chlorine concentration is below the specified level (it also depends on the original water quality), be sure to adjust the amperage and voltage to make the concentration reach the specified level.

Thiosulfuric Acid Titration

< Instruments >

Erlenmeyer flask (100mL - 200mL) Measuring cylinder (50mL)

Measuring pipet or syringe (graduated by 0.1 or 0.5mL) Reagents: Potassium iodide (KI)

Sodium thiosulfate (1/100N)

1)Wash the Erlenmeyer flask, measuring cylinder and measuring pipet with tap water.

2)Take 35.4mL of acid water in the cylinder, and pour it gently into the flask.

3)Put some potassium iodide (two or three grains) into the flask, and stir it lightly. The acid water will turn orange.

4)Take some sodium thiosulfate (1/100N) with the pipet, and read it.

5)Drop the sodium thiosulfate (1/100N) little by little into the flask while stirring it lightly. When the acid water starts losing its color, drop the reagent with special care.

6)When the acid water turns from orange into clear, stop dropping the reagent and read the pipet.

7)The dropping amount (mL) x 10 will be the available chlorine concentration (mg/L). For example, if the dropping amount is 4.5mL, the available chlorine concentration will be 45mg/L.

[c] Cell Replace Lamp [No. 8]

The flashing Cell Replace Lamp indicates that the Electrolytic Cell has run for 2900 - 3000 hours and should be replaced soon.

The lighting Cell Replace Lamp indicates that the Electrolytic Cell has run for 3000 hours or more and needs immediate replacement.

[d] Water Softener [No. 15]

Carefully read the instructions provided with the water softener, and use it properly.

Check that the water softener is set to start regeneration while electrolyzed water is not dispensed (ex. 2:00AM).

30

U8AA5540012

Image 32
Contents Model ROX-20TA-U Contents General Information Safety Instructions U8AA5540012 Product Information DIMENSIONS/CONNECTIONS Features of Strong Acid Water Principle of Strong Acid Water Generation II. Construction General U8AA5540012 Control Panel Display Panel Control BOX Outlet Valves Option Remote Controller OptionWater Tank Float Switches Option U8AA5540012 Adjustment Procedure A1 Cell LifecycleLighting A2 Amperage A3 VoltageA4 Cell Reverse Time A5 Amperage Accumulation TimeA6 Storage Mode/Hand-washing Mode A7 Cell Running/Reverse Time Reset A8 Initial Flush Cycle TimeA9 Automatic Dispensing Control Functions and Adjustment of Check Items Checking ProcedureLighting Flashing C1 Output Conditions C2 Input ConditionsOperation Flow Chart Set CheckIV. Technical Information Water Circuit Wiring Diagram Performance Data PH and Amperage Service Information MAINTENANCE/INSPECTION Acid Water pH, Alkaline Water pH No Available Chlorine Concentration Acid NoThiosulfuric Acid Titration Cell Replace Lamp NoService Diagnosis Cartridge Filter NoU8AA5540012 U8AA5540012 MINAMIYAKATA, SAKAE, TOYOAKE, Aichi 470-1194 Japan