2. CONTROL PANEL
[1]
[10]
[2]
[3]
[4]
[5]
[9]
[6]
[7] | [8] |
[1] Display Window
Displays the operation time, amperage or voltage during the normal operation and error codes in case of trouble.
[2] Operation Time Lamp
Display Window displays operation time (h) when this lamp is on. [3] Amperage Lamp
Display Window displays amperage (A) when this lamp is on. [4] Voltage Lamp
Display Window displays voltage (V) when this lamp is on. [5] Display Select Button
Switches the display of the Display Window. [6] Flush Button
Functions as a switch to flush the pipes beyond the acid and alkaline water outlets. [7] Set Button
Only qualified service personnel or installer may press this button to adjust various set values.
[8] Amperage Control Volume
Only qualified service personnel may turn this control to change the set amperage. [9] Voltage Control Volume
Only qualified service personnel may turn this control to change the set voltage. [10] Power Switch
Turns the unit on and off.
U8AA5540012 | 9 |