Hoshizaki ROX-20TA-U service manual Control BOX

Page 13

4. CONTROL BOX

[1]

[2]

[3]

[4]

[13]

[5]

[12]

[6]

[11]

[10]

[9]

[8]

[7]

[1] Switching Regulator

Supplies power to start the Programmable Controller, etc.

[2] Noise Board

Board to remove noise in the unit. [3] Current Sensor

Reads amperage in the Electrolytic Cell. [4] Water Level Sensor Board

Board to control the Water Level Sensor. [5] Operation Board

Board with switches to operate the Control Panel, etc. [6] Magnetic Contactor

Switches polarity of the Electrolytic Cell. [7] Relay 1

For [10] DC Power Supply.

[8] Relay 2

Controls the water level in the Water Tank. [9] Relay 3

Switches the electrolyzed water display of the Remote Controller. [10] DC Power Supply

Power supply for cells to generate electrolyzed water.

[11]Programmable Controller Manages all controls of the unit.

[12]Noise Filter

Removes noise from 1. [19] Electromagnetic Metering Pump.

[13]Ferrite Core (not shown) Removes noise in the unit.

U8AA5540012

11

Image 13
Contents Model ROX-20TA-U Contents General Information Safety Instructions U8AA5540012 Product Information DIMENSIONS/CONNECTIONS Features of Strong Acid Water Principle of Strong Acid Water Generation II. Construction General U8AA5540012 Control Panel Display Panel Control BOX Water Tank Float Switches Option Remote Controller OptionOutlet Valves Option U8AA5540012 A1 Cell Lifecycle Adjustment ProcedureLighting A3 Voltage A2 AmperageA5 Amperage Accumulation Time A4 Cell Reverse TimeA6 Storage Mode/Hand-washing Mode A8 Initial Flush Cycle Time A7 Cell Running/Reverse Time ResetA9 Automatic Dispensing Control Checking Procedure Functions and Adjustment of Check ItemsLighting Flashing C2 Input Conditions C1 Output ConditionsSet Check Operation Flow ChartIV. Technical Information Water Circuit Wiring Diagram Performance Data PH and Amperage Service Information MAINTENANCE/INSPECTION Available Chlorine Concentration Acid No Acid Water pH, Alkaline Water pH NoThiosulfuric Acid Titration Cell Replace Lamp NoCartridge Filter No Service DiagnosisU8AA5540012 U8AA5540012 MINAMIYAKATA, SAKAE, TOYOAKE, Aichi 470-1194 Japan