Hoshizaki ROX-20TA-U service manual Service Information MAINTENANCE/INSPECTION

Page 31

V. SERVICE INFORMATION

1. MAINTENANCE/INSPECTION

Check the following items during maintenance or inspection in normal condition. If any of them is found abnormal or defective, repair, replace or adjust it properly.

No.

Inspection

Remedy

 

 

Item

Check

 

 

 

 

 

 

1

Acid Water pH

Within specified range?

Check by pH tester.

 

 

 

 

2

Alkaline Water pH

Within specified range?

Check by pH tester.

 

 

 

 

3

Available Chlorine

Within specified range?

Check by accessory chlorine test

 

Concentration (Acid)

 

paper or thiosulfuric acid titration.

 

 

 

 

4

Flow Rate (Acid/Alkaline)

Within specified range?

Check by beaker.

 

 

 

 

5

Ambient Temp.

Within specified range?

Check by thermometer.

 

 

 

 

6

Water Supply Temp.

Within specified range?

Check by thermometer.

 

 

 

 

7

Water Supply Pressure

Within specified range?

Check by water pressure gauge.

 

 

 

 

8

Cell Replace Lamp

Flashing or lighting?

Visually check.

 

 

 

 

9

Salt Water Tank

No dirt buildup?

Visually check.

 

 

No salt deposit at bottom?

Visually check.

 

 

 

 

10

Filter

Not clogged with dirt?

Visually check.

 

 

 

 

11

Water Circuit

No water leak?

Visually check.

 

 

 

 

12

Attachment Plug

Securely plugged in?

Visually check.

 

 

Not hot?

Check.

 

 

 

 

13

Exterior

Clean?

Visually check.

 

 

 

 

14

Float Switch

Free of scale?

Visually check.

 

 

Working properly?

Check for proper operation.

 

 

 

 

15

Water Softener

Water softened?

Check water sample.

 

 

Working properly?

Check.

 

 

Set to regenerate water while

Check.

 

 

unit is out of service?

Check.

 

 

Proper amount of salt inside?

 

 

 

 

16

Cartridge Filter

Pressure difference within

Visually check.

 

 

specified range?

 

 

 

 

 

17

Remote Controller

Water outlet not blocked?

Visually check.

 

 

Working properly?

Check for proper operation.

 

 

 

 

18

Labels

Attached firmly in place?

Visually check.

 

 

 

 

U8AA5540012

29

Image 31
Contents Model ROX-20TA-U Contents General Information Safety Instructions U8AA5540012 Product Information DIMENSIONS/CONNECTIONS Features of Strong Acid Water Principle of Strong Acid Water Generation II. Construction General U8AA5540012 Control Panel Display Panel Control BOX Water Tank Float Switches Option Remote Controller OptionOutlet Valves Option U8AA5540012 A1 Cell Lifecycle Adjustment ProcedureLighting A3 Voltage A2 AmperageA5 Amperage Accumulation Time A4 Cell Reverse TimeA6 Storage Mode/Hand-washing Mode A8 Initial Flush Cycle Time A7 Cell Running/Reverse Time ResetA9 Automatic Dispensing Control Checking Procedure Functions and Adjustment of Check ItemsLighting Flashing C2 Input Conditions C1 Output ConditionsSet Check Operation Flow ChartIV. Technical Information Water Circuit Wiring Diagram Performance Data PH and Amperage Service Information MAINTENANCE/INSPECTION Cell Replace Lamp No Acid Water pH, Alkaline Water pH NoAvailable Chlorine Concentration Acid No Thiosulfuric Acid TitrationCartridge Filter No Service DiagnosisU8AA5540012 U8AA5540012 MINAMIYAKATA, SAKAE, TOYOAKE, Aichi 470-1194 Japan