Hoshizaki ROX-20TA-U service manual C1 Output Conditions, C2 Input Conditions

Page 25

12)When the desired check item code is displayed, push the Flush Button one time. The Display Window will show the present check item information.

13)To finish checking, press the Display Button and Flush Button together to show “C 1”, “C 2”... in the Display Window.

14)When the Display Window shows one of those check item codes, keep on pushing the Set Button. Check that the Display Window reads “CHE.”

15)While pushing the Set Button, press the Display Button one time.

16)Check that the Display Window reads “Nor.”, which means the device is in the normal mode.

17)Release the Set Button.

18)This is the end of checking.

C1: Output Conditions

The lighting LED shows the applicable output is ON. Relay X3 Magnet Switch

 

Relay X1

 

Gear Motor

None

 

Pulse signal to

Water Valve

Metering Pump

 

C2: Input Conditions

Output to DC power

supply CNT-TOG

The lighting LED shows the applicable input is ON.

Direction Microswitch Location Microswitch

Display Button

Flow Rate Switch

None

Set Button

 

Max. Water Level

Flush Button

Level Sensor

(Float Switch ON)

 

 

U8AA5540012

23

Image 25
Contents Model ROX-20TA-U Contents General Information Safety Instructions U8AA5540012 Product Information DIMENSIONS/CONNECTIONS Features of Strong Acid Water Principle of Strong Acid Water Generation II. Construction General U8AA5540012 Control Panel Display Panel Control BOX Water Tank Float Switches Option Remote Controller OptionOutlet Valves Option U8AA5540012 A1 Cell Lifecycle Adjustment ProcedureLighting A3 Voltage A2 AmperageA5 Amperage Accumulation Time A4 Cell Reverse TimeA6 Storage Mode/Hand-washing Mode A8 Initial Flush Cycle Time A7 Cell Running/Reverse Time ResetA9 Automatic Dispensing Control Checking Procedure Functions and Adjustment of Check ItemsLighting Flashing C2 Input Conditions C1 Output ConditionsSet Check Operation Flow ChartIV. Technical Information Water Circuit Wiring Diagram Performance Data PH and Amperage Service Information MAINTENANCE/INSPECTION Available Chlorine Concentration Acid No Acid Water pH, Alkaline Water pH NoThiosulfuric Acid Titration Cell Replace Lamp NoCartridge Filter No Service DiagnosisU8AA5540012 U8AA5540012 MINAMIYAKATA, SAKAE, TOYOAKE, Aichi 470-1194 Japan