Hoshizaki ROX-20TA-U service manual Functions and Adjustment of Check Items, Checking Procedure

Page 23

2. FUNCTIONS AND ADJUSTMENT OF CHECK ITEMS

The water electrolyzer is provided with the ten check items of the following functions:

No.

Check Items

Functions

 

 

 

C1

Output Conditions

Displays all the present output conditions in the

 

 

Display Window on the Control Panel.

 

 

 

C2

Input Conditions

Displays all the present input conditions in the

 

 

Display Window on the Control Panel.

 

 

 

C3

Present Average Amperage (A)

Displays the average amperage at present.

 

 

 

C4

Present Stroke Speed (spm)

Displays the stroke speed at present.

 

 

 

C5

Present Cell Reverse Time (h)

Displays the cell reverse time at present.

 

 

 

C6

Last Error Code

Displays the error code of the last error.

 

 

 

C7

Last Error Cell Running Time (h)

Displays the cell running time of the last error.

 

 

 

C8

Last Error Cell Reverse Time (m)

Displays the cell reverse time of the last error.

 

 

 

C9

Last Error Average Amperage (A)

Displays the average amperage of the last error.

 

 

 

C10

Last Error Stroke Speed (spm)

Displays the stroke speed of the last error.

 

 

 

CHECKING PROCEDURE

1)Run the electrolyzer to dispense electrolyzed water or to turn on the Add Salt Water Lamp or the Service Call Lamp.

2)Open the Door.

3)The Display Window on the Control Panel shows the present cell lifecycle, amperage (A) or voltage (V), or an error code. Keep on pushing the Set Button.

4)Check that the Display Window reads “Nor.”, which means the unit is in the normal mode.

Lighting

Lighting

U8AA5540012

21

Image 23
Contents Model ROX-20TA-U Contents General Information Safety Instructions U8AA5540012 Product Information DIMENSIONS/CONNECTIONS Features of Strong Acid Water Principle of Strong Acid Water Generation II. Construction General U8AA5540012 Control Panel Display Panel Control BOX Outlet Valves Option Remote Controller OptionWater Tank Float Switches Option U8AA5540012 A1 Cell Lifecycle Adjustment ProcedureLighting A3 Voltage A2 AmperageA5 Amperage Accumulation Time A4 Cell Reverse TimeA6 Storage Mode/Hand-washing Mode A8 Initial Flush Cycle Time A7 Cell Running/Reverse Time ResetA9 Automatic Dispensing Control Checking Procedure Functions and Adjustment of Check ItemsLighting Flashing C2 Input Conditions C1 Output ConditionsSet Check Operation Flow ChartIV. Technical Information Water Circuit Wiring Diagram Performance Data PH and Amperage Service Information MAINTENANCE/INSPECTION Cell Replace Lamp No Acid Water pH, Alkaline Water pH NoAvailable Chlorine Concentration Acid No Thiosulfuric Acid TitrationCartridge Filter No Service DiagnosisU8AA5540012 U8AA5540012 MINAMIYAKATA, SAKAE, TOYOAKE, Aichi 470-1194 Japan