9. Error Codes

In the event of operation outside of normal parameters, the control board identifies the issue with an error code and beeps. If more than one error occurs, the display cycles through the relevant error codes. For service corrections, see "III.B. Error Codes."

 

Error Codes

A1

Wash Tank Auto Fill Error

A2

Internal Booster Tank Auto Fill Error

A3

Wash Tank Water Level Error

o1

Internal Booster Tank Water Level Error 1

(Internal Booster Tank Water Level Float Switch Closed)

 

o2

Internal Booster Tank Water Level Error 2

(Internal Booster Tank Water Level Float Switch Open)

 

H1

Wash Tank Thermistor Error (short)

H2

Wash Tank Thermistor Error (open)

H3

Internal Booster Tank Thermistor Error (short)

H4

Internal Booster Tank Thermistor Error (open)

H5

ROM/RAM Error

H6

EEPROM Error

H7

Phase Reversal Error

10. Buzzer

At the end of an auto fill cycle or other mode operation, the buzzer turns on for 0.1 second and off for 0.1 second 10 times.

In case of an error, the buzzer turns on for 0.1 second and off for 0.9 second repeatedly until the error is reset. To turn off the beep, press the down button.

When a button is pressed, the buzzer turns on for 0.1 second.

To adjust the buzzer volume, use the volume control on the control board.

11. Special Modes

a) Internal Booster Tank Energy Saving Mode

The internal booster tank energy saving mode allows the internal booster tank temperature to drop during periods of inactivity. To activate or deactivate the internal booster tank energy saving mode, see " Internal Booster Tank Energy Saving Mode" (service menu item 14) in "II.D.7.b) Service Menu Chart."

After a period of inactivity from 0 to 99 minutes (service menu item 16), the temperature to maintain is dropped to the setpoint minus 0°F to 40°F (0°C to 22°C) (service menu item 15).

Adjust the water temperature drop so that the rinse (internal booster tank) water temperature rises enough to be at least 180°F (82°C) after the wash cycle.

The minimum rinse (internal booster tank) water temperature for the unit to switch out of the wash cycle and into the rinse cycle can be set from 180°F to 185°F (82°C to 85°C) (service menu item 17). If the minimum temperature has not been reached at the end of the preset wash cycle time (service menu item 01 or 02), the wash cycle is extended up to 60 seconds

23

Image 28
Contents Model JWE-620UA-6B Hoshizaki AMERICA, INC Contents Page Important Safety Information Specifications Specification Sheet DisplayNameplate Rating Dimensions/Connections II. General Information A. Construction DishwasherInternal Booster Tank Control Box Auxiliary Code U-1, U-2, U-3, V-0, A-0Auxiliary Code A-1 and Later Auto Fill Cycle Sequence of OperationAuto Fill lamp flashing and RINSE, STANDARD, or Long lamp on Wash Cycle STANDBY/CLEANING Button Start Rinse CycleRinse lamp flashing DrainSequence of Operation Flow Chart Auxiliary Code A-1 and Later Control Board and Operation Board Control Board LocationControl Board Layout CN5Control Board Diagram CN9X10 Error Codes Mode LampsReady Lamp Auto Fill LampMode Button STANDBY/CLEANING ButtonService Menu Access Standby LampService Menu Chart Auxiliary Code U-1, U-2, U-3, V-0, A-0 DefaultService Menu Chart Auxiliary Code A-1 and Later Temperature Display Error Codes Internal Booster Tank Energy Saving ModeBuzzer Special ModesConsecutive Rinse Mode Continuous Wash ModeAlert Function Auxiliary Code A-1 and Later OFF Diagnostic Procedure III. Service DiagnosisSwitch Open/Closed Display Mode Page Error Codes Error Code TableError Code Log Error Code Details Auto Fill Error A1Internal Booster Tank Auto Fill Error A2 Wash Tank Water Level Error A3 Defective Replace Control Board Repair or replace Replace Wash Tank Thermistor Error H1, H2 Internal Booster Tank Thermistor Error H3, H4 ROM/RAM Error H5 Eeprom Error H6Phase Reversal Error H7 Service Flow Charts Unit Will Not StartPage Dishes Not Clean Page Inadequate Rinse Dishwasher Will Not Start When Door Closed No or Inadequate Detergent/Rinse Aid Supply Wash Tank Water BoilsWash Tank Water Not Draining Float Switch Check Float Switch Check and CleaningFloat Switch Cleaning Thermistor Check Accessing the Control Box IV. Removal and Replacement of ComponentsRemoval of Panels Page Removal and Replacement of Internal Booster Tank Removal and Replacement of Wash Pump Motor Removal and Replacement of Rinse Pump Motor Removal and Replacement of Handle Removal and Replacement of Door Removal and Replacement of Spring Unit Removal and Replacement of SpringAdjustment of Door Opening/Closing Force Removal and Replacement of Flush Pipe Packing Installation Instructions Removal and Replacement of Thermistor Control Board Removal and Replacement of Control Board or Operation BoardOperation Board Page Cleaning and Maintenance Instructions Daily Maintenance Pump Filter Water Level Sensor Location Front Self-Cleaning Weekly Maintenance Monthly InspectionDescaling As Required Shutdown Long Storage, Relocation, Disposal, Transfer VI. Operating Instructions VII. Technical Information Water Circuit Wiring Diagram Auxiliary Code U-1, U-2, U-3, V-0, A-0Auxiliary Code A-1 and Later