3) Header (Rinse Spray Arm) and Double Pipe Connection

M. Removal and Replacement of Thermistor

CAUTION

1.The thermistors are fragile; handle very carefully.

2.Always use the recommended sealant (high thermal conductive type), Model KE4560RTV manufactured by SHINETSU SILICONE, Part Code 60Y000-11, or Part Code 4A0683-01 or equivalent.

3.Do not shorten or cut the thermistor leads.

1)Move the power switch (GFCI) to the “OFF” position, then turn off the power supply. Lockout/Tagout to prevent the power from being turned back on inadvertently.

2)Remove the front panel.

3)Remove the plastic bag covering the thermistor connector, then disconnect the thermistor connector. If replacing the wash tank thermistor, disconnect the leads from the wash tank electrode. If replacing the internal booster tank thermistor, disconnect the closed end connectors for the internal booster tank water level float switch and the internal booster tank backup water level float switch.

4)Remove the tape or ties securing the thermistor leads, then pull out the thermistor from the wash tank or internal booster tank straight towards you.

5)Clean out all old sealant from inside the thermistor hole.

6)Route the wires from the new thermistor connector through the existing black plastic sleeve.

7)Apply the recommended sealant (KE4560RTV, Part Code 60Y000-11 or 4A0683-01) to the end of the new thermistor, then insert the thermistor quickly and securely.

8)Use tape or ties to secure the thermistor leads in their correct position.

9)Reconnect the thermistor connector and the wash tank electrode leads or the internal booster tank water level float switch and internal booster tank backup water level float switch leads, then bag and tie them.

10)Replace the front panel in its correct position.

60

Image 65
Contents Model JWE-620UA-6B Hoshizaki AMERICA, INC Contents Page Important Safety Information Display Specifications Specification SheetNameplate Rating Dimensions/Connections Dishwasher II. General Information A. ConstructionInternal Booster Tank Auxiliary Code U-1, U-2, U-3, V-0, A-0 Control BoxAuxiliary Code A-1 and Later Auto Fill lamp flashing and RINSE, STANDARD, or Long lamp on Sequence of OperationAuto Fill Cycle Wash Cycle Rinse Cycle STANDBY/CLEANING Button StartDrain Rinse lamp flashingSequence of Operation Flow Chart Auxiliary Code A-1 and Later Control Board Location Control Board and Operation BoardCN5 Control Board LayoutCN9 Control Board DiagramX10 Mode Lamps Error CodesReady Lamp Auto Fill LampSTANDBY/CLEANING Button Mode ButtonService Menu Access Standby LampDefault Service Menu Chart Auxiliary Code U-1, U-2, U-3, V-0, A-0Service Menu Chart Auxiliary Code A-1 and Later Temperature Display Internal Booster Tank Energy Saving Mode Error CodesBuzzer Special ModesAlert Function Auxiliary Code A-1 and Later Continuous Wash ModeConsecutive Rinse Mode OFF Switch Open/Closed Display Mode III. Service DiagnosisDiagnostic Procedure Page Error Code Table Error CodesError Code Log Auto Fill Error A1 Error Code DetailsInternal Booster Tank Auto Fill Error A2 Wash Tank Water Level Error A3 Defective Replace Control Board Repair or replace Replace Wash Tank Thermistor Error H1, H2 Internal Booster Tank Thermistor Error H3, H4 Eeprom Error H6 ROM/RAM Error H5Phase Reversal Error H7 Unit Will Not Start Service Flow ChartsPage Dishes Not Clean Page Inadequate Rinse Dishwasher Will Not Start When Door Closed Wash Tank Water Boils No or Inadequate Detergent/Rinse Aid SupplyWash Tank Water Not Draining Float Switch Cleaning Float Switch Check and CleaningFloat Switch Check Thermistor Check Removal of Panels IV. Removal and Replacement of ComponentsAccessing the Control Box Page Removal and Replacement of Internal Booster Tank Removal and Replacement of Wash Pump Motor Removal and Replacement of Rinse Pump Motor Removal and Replacement of Handle Removal and Replacement of Door Removal and Replacement of Spring Removal and Replacement of Spring UnitAdjustment of Door Opening/Closing Force Removal and Replacement of Flush Pipe Packing Installation Instructions Removal and Replacement of Thermistor Operation Board Removal and Replacement of Control Board or Operation BoardControl Board Page Cleaning and Maintenance Instructions Daily Maintenance Pump Filter Water Level Sensor Location Front Self-Cleaning Monthly Inspection Weekly MaintenanceDescaling As Required Shutdown Long Storage, Relocation, Disposal, Transfer VI. Operating Instructions VII. Technical Information Water Circuit Auxiliary Code U-1, U-2, U-3, V-0, A-0 Wiring DiagramAuxiliary Code A-1 and Later