C. Removal and Replacement of Internal Booster Tank

1)Move the power switch (GFCI) to the “OFF” position, then turn off the power supply. Lockout/Tagout to prevent the power from being turned back on inadvertently.

2)Close the water supply line shut-off valve.

3)Use the internal booster tank drain hose to drain the internal booster tank. WARNING!

To avoid possible burns, allow the internal booster tank water temperature to fall below 104°F (40°C) before draining.

4)Move the power switch (GFCI) to the “ON” position. Press the “ON/OFF” button to turn on the unit. Leave the unit on for 3 to 5 seconds to operate the water valve and remove any water inside the water supply pipe. Move the power switch (GFCI) to the “OFF” position, then turn off the power supply. Lockout/Tagout to prevent the power from being turned back on inadvertently.

5)Loosen and disconnect the rinse pump discharge line.

6)Remove the band (clip) connecting the rinse pump and internal booster tank.

7)Unscrew and remove the rinse pump from the internal booster tank.

8)Loosen and remove the nut connecting the water valve and water supply pipe.

9)Remove the screw securing the internal booster tank and the connector for the water valve. Pull out the internal booster tank.

10)Unscrew the internal booster tank cover.

11)To replace, reverse the above procedure.

Internal Booster Tank Cover

 

Mounting Screw

Water Supply Pipe

 

Rinse Pump

 

Discharge Line

Water Valve

 

 

Wash Pump Motor

Internal Booster Tank

 

Drain Hose

 

Internal Booster Tank

Control Box

Cover

Internal Booster Tank

 

Internal Booster Tank Mounting Screw

Band

Rinse Pump Motor Power Switch

Mounting Screw (GFCI)

Rinse Pump Motor

51

Image 56
Contents Model JWE-620UA-6B Hoshizaki AMERICA, INC Contents Page Important Safety Information Specifications Specification Sheet DisplayNameplate Rating Dimensions/Connections II. General Information A. Construction DishwasherInternal Booster Tank Control Box Auxiliary Code U-1, U-2, U-3, V-0, A-0Auxiliary Code A-1 and Later Auto Fill lamp flashing and RINSE, STANDARD, or Long lamp on Sequence of OperationAuto Fill Cycle Wash Cycle STANDBY/CLEANING Button Start Rinse CycleRinse lamp flashing DrainSequence of Operation Flow Chart Auxiliary Code A-1 and Later Control Board and Operation Board Control Board LocationControl Board Layout CN5Control Board Diagram CN9X10 Error Codes Mode LampsReady Lamp Auto Fill LampMode Button STANDBY/CLEANING ButtonService Menu Access Standby LampService Menu Chart Auxiliary Code U-1, U-2, U-3, V-0, A-0 DefaultService Menu Chart Auxiliary Code A-1 and Later Temperature Display Error Codes Internal Booster Tank Energy Saving ModeBuzzer Special ModesAlert Function Auxiliary Code A-1 and Later Continuous Wash ModeConsecutive Rinse Mode OFF Switch Open/Closed Display Mode III. Service DiagnosisDiagnostic Procedure Page Error Codes Error Code TableError Code Log Error Code Details Auto Fill Error A1Internal Booster Tank Auto Fill Error A2 Wash Tank Water Level Error A3 Defective Replace Control Board Repair or replace Replace Wash Tank Thermistor Error H1, H2 Internal Booster Tank Thermistor Error H3, H4 ROM/RAM Error H5 Eeprom Error H6Phase Reversal Error H7 Service Flow Charts Unit Will Not StartPage Dishes Not Clean Page Inadequate Rinse Dishwasher Will Not Start When Door Closed No or Inadequate Detergent/Rinse Aid Supply Wash Tank Water BoilsWash Tank Water Not Draining Float Switch Cleaning Float Switch Check and CleaningFloat Switch Check Thermistor Check Removal of Panels IV. Removal and Replacement of ComponentsAccessing the Control Box Page Removal and Replacement of Internal Booster Tank Removal and Replacement of Wash Pump Motor Removal and Replacement of Rinse Pump Motor Removal and Replacement of Handle Removal and Replacement of Door Removal and Replacement of Spring Unit Removal and Replacement of SpringAdjustment of Door Opening/Closing Force Removal and Replacement of Flush Pipe Packing Installation Instructions Removal and Replacement of Thermistor Operation Board Removal and Replacement of Control Board or Operation BoardControl Board Page Cleaning and Maintenance Instructions Daily Maintenance Pump Filter Water Level Sensor Location Front Self-Cleaning Weekly Maintenance Monthly InspectionDescaling As Required Shutdown Long Storage, Relocation, Disposal, Transfer VI. Operating Instructions VII. Technical Information Water Circuit Wiring Diagram Auxiliary Code U-1, U-2, U-3, V-0, A-0Auxiliary Code A-1 and Later