Hoshizaki L1F015102 instruction manual Water Supply and Drain Connections See Figs

Page 12

from 6” (15.2 cm) to 7” (17.8 cm). Screw the legs tightly into the tapped holes in the base (see Fig. 3). Handle the icemaker carefully not to damage the exterior.

Tapped Hole

(Leg Mounting)

Base

Adjustable Leg

Max. 0.2” (5mm) [0.3°]

Fig. 2

Fig. 3

F. Water Supply and Drain Connections - See Figs. 4 and 5

CAUTION

To prevent damage to equipment, do not operate this icemaker when the water supply is OFF, or if the pressure is below 10 PSIG (0.7 bar). Do not run the icemaker until proper water pressure is reached.

*Water supply inlet is 1/2” female pipe thread (FPT).

*A water supply line shut-off valve and drain valve should be installed. A minimum of 3/8” OD copper tubing is recommended for the water supply lines.

*Water supply pressure should be a minimum of 10 PSIG (0.7 bar) and a maximum of 113 PSIG (7.5 bar). If the pressure exceeds 113 PSIG (7.5 bar), the use of a pressure reducing valve is required.

*Drain outlet for icemaker dump is 3/4” FPT.

*Drain lines must have 1/4” fall per foot (2 cm per meter) on horizontal runs to get good flow. A vented tee connection is also required for proper flow.

9

Image 12
Contents KM-201BAH KM-260BAH KM-201BWH KM-260BWH Hoshizaki AMERICA, INC Contents Specifications Nameplate Rating KM-260BWHDimensions/Connections KM-201BAHKM-260BAH KM-201BWH KM-260BWH How to Remove Panels See Fig Location Set Up Electrical ConnectionWater Supply and Drain Connections See Figs KM-201BAH KM-201BWH KM-260BWH Final Checklist Startup III. Cleaning and Maintenance Instructions CleaningCleaning Procedure Thumbscrew Bracket L Evaporator Cube Guide Water Tank Sanitizing Procedure Following Cleaning Procedure Maintenance Exterior PanelsStorage Bin and Scoop Preparing the Icemaker for Long Storage Air FilterCondenser Remove the water from the potable water supply lineDrain the potable Water Tank