*Drain lines should not be piped directly to the sewer system. An air gap of a minimum of 2 vertical inches (5 cm) should be between the end of the drain pipes from the icemaker and the floor drain.

*This icemaker should be installed in accordance with applicable national, state and local regulations.

*A plumbing permit and services of a licensed plumber may be required in some areas.

KM-201BAH

KM-260BAHDrain Outlet 3/4” FPT

Water Supply Inlet 1/2” FPT

Shut-off Valve

1/4” fall per foot

To approved floor drain

Drain Valve

Two-inch (5 cm) air gap

Separate piping to approved drain. Leave a two-inch (5 cm) vertical air gap between the end of each pipe and the drain.

Floor

Drain

Fig. 4

10

Image 13
Contents KM-201BAH KM-260BAH KM-201BWH KM-260BWH Hoshizaki AMERICA, INC Contents KM-260BWH Specifications Nameplate RatingKM-201BAH Dimensions/ConnectionsKM-260BAH KM-201BWH KM-260BWH How to Remove Panels See Fig Location Electrical Connection Set UpWater Supply and Drain Connections See Figs KM-201BAH KM-201BWH KM-260BWH Final Checklist Startup Cleaning III. Cleaning and Maintenance InstructionsCleaning Procedure Thumbscrew Bracket L Evaporator Cube Guide Water Tank Sanitizing Procedure Following Cleaning Procedure Exterior Panels MaintenanceStorage Bin and Scoop Air Filter Preparing the Icemaker for Long StorageCondenser Remove the water from the potable water supply lineDrain the potable Water Tank