134 | 5 Troubleshooting |
Error message | Description |
|
|
Virus related BIOS message |
|
|
|
BootSector Write !! | A software attempting to write to a |
| drive’s boot sector has been detected. This |
| is flagged as possible virus activity. This |
| message will only be displayed if Virus |
| Detection is enabled in the BIOS setup. |
|
|
VIRUS: Continue (Y/N)? | A possible virus activity is detected. This |
| message will only be displayed if Virus |
| Detection is enabled in the BIOS setup. |
| |
System configuration BIOS message | |
|
|
Error during read/write test of the | |
| secondary DMA controller. |
|
|
DMA Controller Error | Error during read/write test of the DMA |
| controller. |
|
|
Checking NVRAM..Update | Unable to write to the NVRAM block. This |
Failed | message appears when the FLASH part is |
| |
| part (System uses a PROM or EPROM). |
|
|
Microcode Error | Unable to find or load the CPU Microcode |
| Update to the CPU. |
|
|
NVRAM Checksum Bad, | Error while validating the NVRAM data. |
NVRAM Cleared |
|
|
|
Resource Conflict | More than one system device is trying to |
| use the same |
| (Memory or I/O). |
|
|
NVRAM Ignored | The NVRAM data used to store |
| play (PnP) data was not used for system |
| configuration in POST. |
|
|
NVRAM Bad | The NVRAM data used to store |
| Plug’n’Play (PnP) data was not used for |
| system configuration in POST due to a |
| data error. |
|
|