Hoshizaki F-300BAF service manual Problem Possible Cause Remedy

Page 30

Problem

Possible Cause

 

Remedy

 

 

 

 

 

j) Water Control Relay

1. Bad contacts.

1. Replace.

 

 

 

 

 

 

2. Open coil.

2. Replace.

 

 

 

 

 

k) Water Valve

1. Coil winding opened.

1. Replace.

 

 

 

 

 

l) Shut-off Valve

1. Closed.

1. Open.

 

 

 

 

 

 

2. Water failure.

2. Wait until water is

 

 

 

supplied.

 

 

 

 

 

m)Plug and Receptacle

1. Disconnected.

1. Connect.

 

(Control Box)

 

 

 

2. Loose terminal.

2. Repair terminal

 

 

 

 

 

connection.

 

 

 

 

[2] Water does not stop,

a) Float Switch

1. Bad contacts.

1. Check for continuity and

and the gear motor

 

 

replace.

will not start.

 

 

 

 

2. Float does not move

2. Clean or replace.

 

 

 

 

freely.

 

 

 

 

 

 

b) Water Control Relay

1. Contact fused.

1. Replace.

 

 

 

 

 

 

2. Coil winding opened.

2. Replace.

 

 

 

 

 

c) Flush Water Valve

1. Valve seat clogged

1. Clean or replace.

 

 

and water leaking.

 

 

 

 

 

 

d) Hoses

1. Disconnected.

1. Connect.

 

 

 

 

[3] Water has been

a) Bin Control

1. Open

1. Bin full, check for

supplied, but the gear

 

 

continuity on proximity

motor will not start.

 

 

switch.

 

 

 

 

 

b) Water Control Relay

1. Low water safety

1. Replace relay.

 

 

circuit open

 

 

 

(bad conacts ).

 

 

 

 

 

 

c) Control Timer

1. Fails to operate gear

1. Check water control relay

 

(Printed Circuit Board)

motor relay.

circuit.

 

 

 

 

 

d) Gear Motor Fuse

1. Blown.

1. Check gear motor

 

 

 

amperage, bearing

 

 

 

wear (see "V. F. 1. Upper

 

 

 

Bearing Wear Check"),

 

 

 

supply voltage.

 

 

 

 

 

e) Gear Motor Thermal

1. Open.

1. Check gear motor

 

Protector

 

bearings, voltage supply.

 

 

 

 

 

f) Gear Motor

1. Open windings.

1. Replace gear motor.

 

 

 

 

 

 

2. Locked bearings

1. Replace gear motor.

 

 

 

 

[4] Gear motor starts,

a) Gear Motor Protect

1. Open coil.

1. Replace.

but compressor will

Relay

 

 

2. Open contacts.

2. Replace.

not start or operates

 

 

 

 

b) Timer Board Relay

1. Bad contacts.

1. Check for continuity and

intermittently.

 

 

replace.

 

 

 

 

 

 

 

 

 

2. Coil winding opened.

2. Replace timer.

 

 

 

 

 

c) Starter

1. Bad contacts.

1. Check for continuity and

 

 

 

replace.

 

 

 

 

 

 

2. Coil winding opened.

2. Replace.

 

 

 

 

 

 

3. Loose connections.

3. Tighten.

 

 

 

 

 

d) Start Capacitor or Run

1. Defective.

1. Replace.

 

Capacitor

 

 

 

 

 

 

30

Image 30
Contents Self-Contained Flaker Model 300BAF Hoshizaki AMERICA, INC Contents Upper Bearing Wear Check Specifications Icemaker 300BAFII. General Information Construction Ice Making Unit Control Box Layout Auxiliary Code K-2 and L-0Auxiliary Code L-1 and M-0 Auxiliary Code M-1 and LaterTimer Board Solid-State Timer Board ControlSequence of Operation Ice Production Check300BAF, F-500BAF Sequence Flow Chart and Component Operation 300BAF Wiring Diagram Auxiliary Code K-1 and EarlierAuxiliary Code K-2 and L-0 Auxiliary Code L-1 and M-0 Auxiliary Code M-1 and Later Sequence of Electrical Circuit Ice Purge Cycle Freeze Cycle Shutdown Cleaning Flush Switch Low Water Safety Spout Safety Switch High Pressure Switch Performance Data ICE ProductionIV. Service Diagnosis Diagnostic Procedure Page Diagnostic Charts No Ice ProductionProblem Possible Cause Remedy Low Ice Production Other Refrigerant Recovery Removal and Replacement of ComponentsService for Refrigerant Lines Evacuation and Recharge R-404ABrazing Removal and Replacement of Compressor Removal and Replacement of Drier Removal and Replacement of Expansion ValvePage Removal and Replacement of Evaporator Assembly Components Removal and Replacement of Cutter Upper Bearing Wear CheckRemoval and Replacement of Extruding Head Removal and Replacement of AugerRemoval and Replacement of Evaporator Page 6b. Lower Housing Removal and Replacement of Gear MotorRemoval and Replacement of Fan Motor Removal and Replacement of Inlet Water ValveRemoval and Replacement of Flush Water Valve Page Cleaning Solution VI. Cleaning and MaintenanceCleaning and Sanitizing Instructions Cleaning ProcedureSanitizing Solution Sanitizing Procedure Initial Sanitizing Procedure FinalPage Storage Bin and Scoop MaintenanceStainless Steel Exterior Air FilterPreparing the Icemaker for Long Storage