Hoshizaki F-300BAF Removal and Replacement of Extruding Head, Removal and Replacement of Auger

Page 40

3.Removal and Replacement of Extruding Head

1)Unplug the unit from the electrical outlet.

2)Remove the panels.

3)Remove the thumbscrews and take off the spout from the evaporator.

4)Loosen the cutter with a wrench and remove it.

5)Remove the allen head cap screws and lift off the extruding head.

6)Place new extruding head in place and tighten down allen head cap screws. If the seals on the allen head cap screws are RED, they must be replaced. If the seals are BLUE, they may be re-used.

7)Replace the cutter and spout. Make sure that the drip bracket is in the channel and that safety bracket B is behind safety bracket A. See Fig. 1.

8)Replace the panels in their correct positions.

9)Plug the unit back in.

4.Removal and Replacement of Auger

1)Drain water from the evaporator by using the flush switch.

2)Unplug the unit from the electrical outlet.

3)Remove the panels.

4)Remove the thumbscrews and take off the spout from the evaporator.

5)Loosen the cutter with a wrench.

6)Remove the allen head cap screws securing the extruding head. Using the cutter, lift out the auger assembly.

7)Remove the cutter and extruding head from the auger and place on the new auger.

8)Install the new auger.

9)Replace the removed parts in the reverse order of which they were removed. When replacing the spout, make sure that the drip bracket is in the channel and that safety bracket B is behind safety bracket A. See Fig. 1.

10)Replace the panels in their correct positions.

11)Plug the unit back in.

5.Removal and Replacement of Evaporator

IMPORTANT

Always install a new drier every time the sealed refrigeration system is opened. Do not replace the drier until after all other repair or replacement has been made.

1)Remove the panels.

2)Drain water from the evaporator by using the flush switch.

3)Unplug the unit from the electrical outlet.

40

Image 40
Contents Self-Contained Flaker Model 300BAF Hoshizaki AMERICA, INC Contents Upper Bearing Wear Check Specifications Icemaker 300BAFII. General Information Construction Ice Making Unit Control Box Layout Auxiliary Code K-2 and L-0Auxiliary Code L-1 and M-0 Auxiliary Code M-1 and LaterTimer Board Solid-State Timer Board ControlSequence of Operation Ice Production Check300BAF, F-500BAF Sequence Flow Chart and Component Operation 300BAF Wiring Diagram Auxiliary Code K-1 and EarlierAuxiliary Code K-2 and L-0 Auxiliary Code L-1 and M-0 Auxiliary Code M-1 and Later Sequence of Electrical Circuit Ice Purge Cycle Freeze Cycle Shutdown Cleaning Flush Switch Low Water Safety Spout Safety Switch High Pressure Switch Performance Data ICE ProductionIV. Service Diagnosis Diagnostic Procedure Page Diagnostic Charts No Ice ProductionProblem Possible Cause Remedy Low Ice Production Other Removal and Replacement of Components Service for Refrigerant LinesRefrigerant Recovery Evacuation and Recharge R-404ABrazing Removal and Replacement of Compressor Removal and Replacement of Drier Removal and Replacement of Expansion ValvePage Removal and Replacement of Evaporator Assembly Components Removal and Replacement of Cutter Upper Bearing Wear CheckRemoval and Replacement of Auger Removal and Replacement of Extruding HeadRemoval and Replacement of Evaporator Page 6b. Lower Housing Removal and Replacement of Gear MotorRemoval and Replacement of Inlet Water Valve Removal and Replacement of Fan MotorRemoval and Replacement of Flush Water Valve Page VI. Cleaning and Maintenance Cleaning and Sanitizing InstructionsCleaning Solution Cleaning ProcedureSanitizing Solution Sanitizing Procedure Initial Sanitizing Procedure FinalPage Maintenance Stainless Steel ExteriorStorage Bin and Scoop Air FilterPreparing the Icemaker for Long Storage