3. Other
Problem | Possible Cause |
| Remedy | |
|
|
|
| |
[1] Abnormal noise | a)Fan Motor | 1. Bearing worn out. | 1. Replace. | |
|
|
|
| |
|
| 2. Fan blade deformed. | 2. Replace fan blade. | |
|
|
|
| |
|
| 3. Fan blade does not | 3. Replace. | |
|
| move freely. |
| |
|
|
|
| |
| b)Compressor | 1. Bearings worn out, or | 1. Replace. | |
|
| cylinder valve broken. |
| |
|
|
|
| |
|
| 2. Mounting pad out of | 2. Reinstall. | |
|
| position. |
| |
|
|
|
| |
| c) Refrigerant Lines | 1. Rub or touch lines or | 1. Replace or separate. | |
|
| other surfaces. |
| |
|
|
|
| |
| d)Gear Motor | 1. Bearing or gear worn | 1. Replace. | |
|
| out / damaged. |
| |
|
|
|
| |
| e)Evaporator | 1. Low refrigerant | 1. Check charge, check for | |
|
| pressures. | possible leak, repair, | |
|
|
| ||
|
|
|
| |
|
| 2. Expansion valve bad. | 2. Replace. | |
|
|
|
| |
|
| 3. Evaporator bad. | 3. Replace. | |
|
|
|
| |
|
| 4. Scale on inside wall of | 4. Use "SCALE AWAY" or | |
|
| freezing cylinder. | ||
|
|
| clean periodically. If the | |
|
|
| water is found hard by | |
|
|
| testing, install a softener. | |
|
|
|
| |
[2] Overflow from | a)Water Supply | 1. Water pressure too | 1. Install a pressure reducing | |
reservoir (water does |
| high. | valve. | |
not stop). |
|
|
| |
b)Water Valve | 1. Diaphragm does not | 1. Clean or replace. | ||
| ||||
|
| close. |
| |
|
|
|
| |
| c) Float Switch | 1. Bad contacts. | 1. Check for continuity and | |
|
|
| replace. | |
|
|
|
| |
| d)Water Control Relay | 1. Bad contacts. | 1. Replace | |
|
|
|
| |
[3] Gear motor protector | a)Power Supply Voltage | 1. Too high or too low. | 1. Connect the unit to a | |
operates frequently or |
|
| power supply of proper | |
fuse blows frequently. |
|
| voltage. | |
|
|
|
| |
| b)Evaporator Assembly | 1. Bearings or auger | 1. Replace bearings or | |
|
| worn out. | auger. | |
|
|
|
| |
| c) Bin Control | 1. Bad contacts. | 1. Check for continuity and | |
|
|
| replace. | |
|
|
|
| |
|
| 2. Actuator does not | 2. Clean shaft and its | |
|
| move freely. | corresponding holes or | |
|
|
| replace bin control. | |
|
|
|
|
32