Hoshizaki F-300BAF service manual IV. Service Diagnosis Diagnostic Procedure

Page 27

IV. Service Diagnosis

A. Diagnostic Procedure

This diagnostic procedure is a sequence check that allows you to diagnose the electrical system and components under normal operating conditions of 70°F or warmer air and 50°F or warmer water temperatures. Before proceeding, check for correct installation, proper voltage per unit nameplate and adequate water supply.

1)Unplug the unit from the electrical outlet and access the control panel.

2)Plug the unit back in. Make sure the flush switch is in the ICE position, then place the power switch in the ON position.

3)Fill Cycle – The water valve energizes. The reservoir begins to fill and the lower float switch closes. Nothing occurs at this time. The reservoir continues to fill and the upper float switch closes, energizng the water control relay. When the water control relay energizes, the inlet water valve de-energizes and the low water safety circuit closes to the timer board. Diagnosis: Check that the water valve fills the reservoir. If not, check for clogged water filters, clogged water valve screen, power supply to the unit, power circuit to the water valve (power switch, high pressure switch, transformer, safety switch, safety relay contacts, fuse, bin control, flush switch, flush relay, flush relay contacts, float switch, water control relay contacts), and the coil on the water valve.

3)Ice Purge Cycle – (short cycle protection) The gear motor and the gear motor protect relay energize, and the 60 second compressor short cycle protection timer starts. Diagnosis: Check that the gear motor starts. If not, check the low water safety circuit on terminals 3 and 4 on the timer board, check for 120 volts on the gear motor relay terminal 8 on the timer board, check the gear motor fuse, thermal protector, and gear motor windings. If the gear motor starts but the auger does not turn: check the gear motor coupling between the auger and the gear motor. If the compressor starts the same time the gear motor starts: Check the compressor relay on the timer board (the black relay on the timer board is the compressor relay).

4)Freeze Cycle – The compressor and fan motor energize, the gear motor, gear motor protect relay, flush switch relay, and the water control relay remain energized. Ice production begins 4 to 6 minutes after the compressor and fan motor start depending on ambient and water conditions. Diagnosis: Check that the compressor and fan motor are running. If not, check for 120 volts on the compressor relay terminal 4 on the timer board (the black relay on the timer board is the compressor relay), check for 120 volts on the gear motor protect relay, check gear motor relay contacts 4 and 6, check voltage on the compressor terminals, check the internal overload (motor protector), the compressor capacitors, and voltage to the fan motor and fan capacitor.

27

Image 27
Contents Self-Contained Flaker Model 300BAF Hoshizaki AMERICA, INC Contents Upper Bearing Wear Check 300BAF Specifications IcemakerII. General Information Construction Ice Making Unit Auxiliary Code K-2 and L-0 Control Box LayoutAuxiliary Code M-1 and Later Auxiliary Code L-1 and M-0Solid-State Timer Board Control Timer BoardIce Production Check Sequence of Operation300BAF, F-500BAF Sequence Flow Chart and Component Operation 300BAF Auxiliary Code K-1 and Earlier Wiring DiagramAuxiliary Code K-2 and L-0 Auxiliary Code L-1 and M-0 Auxiliary Code M-1 and Later Sequence of Electrical Circuit Ice Purge Cycle Freeze Cycle Shutdown Cleaning Flush Switch Low Water Safety Spout Safety Switch High Pressure Switch ICE Production Performance DataIV. Service Diagnosis Diagnostic Procedure Page No Ice Production Diagnostic ChartsProblem Possible Cause Remedy Low Ice Production Other Evacuation and Recharge R-404A Removal and Replacement of ComponentsService for Refrigerant Lines Refrigerant RecoveryBrazing Removal and Replacement of Compressor Removal and Replacement of Expansion Valve Removal and Replacement of DrierPage Removal and Replacement of Evaporator Assembly Components Upper Bearing Wear Check Removal and Replacement of CutterRemoval and Replacement of Extruding Head Removal and Replacement of AugerRemoval and Replacement of Evaporator Page Removal and Replacement of Gear Motor 6b. Lower HousingRemoval and Replacement of Fan Motor Removal and Replacement of Inlet Water ValveRemoval and Replacement of Flush Water Valve Page Cleaning Procedure VI. Cleaning and MaintenanceCleaning and Sanitizing Instructions Cleaning SolutionSanitizing Solution Sanitizing Procedure Final Sanitizing Procedure InitialPage Air Filter MaintenanceStainless Steel Exterior Storage Bin and ScoopPreparing the Icemaker for Long Storage