Hoshizaki F-300BAF service manual

Page 28

5)Refill/Low Water Safety Cycle – As ice is produced, the water level in the reservoir drops. As it drops, the upper float switch and lower float switch open. The upper float switch opens first. Nothing occurs at this time. When the lower float switch opens, the refill begins. The water control relay de-energizes, the low water safety circuit opens (terminals 4 and 6 on the water control relay, 3 and 4 on the timer board), a 90 second countdown timer begins on the timer board, and the inlet water valve energizes. The compressor, fan motor and gear motor continue to run. The upper float switch now has 90 seconds to close before the low water safety timer terminates and shuts down the unit. Once the upper float switch closes, the water control relay energizes, the inlet water valve de-energizes and the low water safety 90 second countdown timer terminates. Diagnosis – Check that the water fill begins. If not, check the lower float switch, voltage to the inlet water valve, the water control relay, water supply, filters, and inlet water valve screen.

7)Shutdown – The bin fills and activates the bin control proximity switch. 90 seconds later the compressor and fan motor de-energize, then 60 seconds later the gear motor de-energizes. Diagnosis: Check that the bin control paddle is activated and that

the proximity switch opens. If the compressor and gear motor fail to stop, check the proximity switch and timer board relays.

28

Image 28
Contents Self-Contained Flaker Model 300BAF Hoshizaki AMERICA, INC Contents Upper Bearing Wear Check Specifications Icemaker 300BAFII. General Information Construction Ice Making Unit Control Box Layout Auxiliary Code K-2 and L-0Auxiliary Code L-1 and M-0 Auxiliary Code M-1 and LaterTimer Board Solid-State Timer Board ControlSequence of Operation Ice Production Check300BAF, F-500BAF Sequence Flow Chart and Component Operation 300BAF Wiring Diagram Auxiliary Code K-1 and EarlierAuxiliary Code K-2 and L-0 Auxiliary Code L-1 and M-0 Auxiliary Code M-1 and Later Sequence of Electrical Circuit Ice Purge Cycle Freeze Cycle Shutdown Cleaning Flush Switch Low Water Safety Spout Safety Switch High Pressure Switch Performance Data ICE ProductionIV. Service Diagnosis Diagnostic Procedure Page Diagnostic Charts No Ice ProductionProblem Possible Cause Remedy Low Ice Production Other Removal and Replacement of Components Service for Refrigerant LinesRefrigerant Recovery Evacuation and Recharge R-404ABrazing Removal and Replacement of Compressor Removal and Replacement of Drier Removal and Replacement of Expansion ValvePage Removal and Replacement of Evaporator Assembly Components Removal and Replacement of Cutter Upper Bearing Wear CheckRemoval and Replacement of Auger Removal and Replacement of Extruding HeadRemoval and Replacement of Evaporator Page 6b. Lower Housing Removal and Replacement of Gear MotorRemoval and Replacement of Inlet Water Valve Removal and Replacement of Fan MotorRemoval and Replacement of Flush Water Valve Page VI. Cleaning and Maintenance Cleaning and Sanitizing InstructionsCleaning Solution Cleaning ProcedureSanitizing Solution Sanitizing Procedure Initial Sanitizing Procedure FinalPage Maintenance Stainless Steel ExteriorStorage Bin and Scoop Air FilterPreparing the Icemaker for Long Storage