Manitowoc Ice Q 800 manual Section General Information, Owner Warranty Registration Card

Page 5

Section 1

General Information

Section 1

General Information

Owner Warranty Registration Card

GENERAL

Warranty coverage begins the day your new ice machine is installed.

Important

Complete and mail the OWNER WARRANTY REGISTRATION CARD as soon as possible to validate the installation date.

If you do not return your OWNER WARRANTY REGISTRATION CARD, Manitowoc will use the date of sale to the Manitowoc Distributor as the first day of warranty coverage for your new ice machine.

Warranty Coverage

GENERAL

The following Warranty outline is provided for your convenience. For a detailed explanation, read the warranty bond shipped with each product.

Contact your local Manitowoc representative or Manitowoc Ice, Inc. if you need further warranty information.

Important

This product is intended exclusively for commercial application. No warranty is extended for personal, family, or household purposes.

PARTS

1.Manitowoc warrants the ice machine against defects in materials and workmanship, under normal use and service for three (3) years from the date of original installation.

2.The evaporator and compressor are covered by an additional two (2) year (five years total) warranty beginning on the date of the original installation.

LABOR

1.Labor required to repair or replace defective components is covered for three (3) years from the date of original installation.

2.The evaporator is covered by an additional two

(2) year (five years total) labor warranty beginning on the date of the original installation..

EXCLUSIONS

The following items are not included in the ice machine’s warranty coverage:

1.Normal maintenance, adjustments and cleaning as outlined in this manual.

2.Repairs due to unauthorized modifications to the ice machine or use of non-standard parts without prior written approval from Manitowoc Ice, Inc.

3.Damage caused by improper installation of the ice machine, electrical supply, water supply or drainage, or damage caused by floods, storms, or other acts of God.

4.Premium labor rates due to holidays, overtime, etc.; travel time; flat rate service call charges; mileage and miscellaneous tools and material charges not listed on the payment schedule. Additional labor charges resulting from the inaccessibility of equipment are also excluded.

5.Parts or assemblies subjected to misuse, abuse, neglect or accidents.

6.Damage or problems caused by installation, cleaning and/or maintenance procedures inconsistent with the technical instructions provided in this manual.

7.This product is intended exclusively for commercial application. No warranty is extended for personal, family, or household purposes.

AUTHORIZED WARRANTY SERVICE

To comply with the provisions of the warranty, a refrigeration service company, qualified and authorized by your Manitowoc distributor, or a Contracted Service Representative must perform the warranty repair.

Normal maintenance, adjustments and cleaning as outlined in this manual are not covered by the warranty.

1-1

Image 5
Contents Marine 800 Ice Machine Installation Owner/Operator Use and Care ManualProcedural Notices Safety NoticesTable of Contents Intentionally Left Blank Warranty Coverage Owner Warranty Registration CardSection General Information Section General InformationGeneral Information Section Section Installation Instructions Section Installation InstructionIce Machine Dimensions GeneralLocation of Ice Machine Installation Instructions SectionLeveling the Ice Storage Bin Leveling Leg and FootElectrical Wiring Connections Section Installation InstructionsElectrical Service Water Supply and Drain Line SIZING/CONNECTIONS Water Service/DrainsDrain Connections Water Supply and Drain Line Sizing Illustration Typical Water Supply Drain InstallationPersonnel Injury Potential Installation ChecklistBefore Starting the Ice Machine Component Identification Section Ice Machine OperationSection Ice Machine Operation Ice Making Sequence of Operation Ice Machine Operation SectionOperational Checks Ice Thickness AdjustmentWater Level Check Water Level CheckHarvest Sequence Water Purge Water Purge AdjustmentSection Maintenance Section MaintenanceMANITOWOC’S Patented Cleaning or Sanitizing Technology WATER-COOLED Condenser and Water Regulating ValveInterior Cleaning and Sanitizing Maintenance SectionCleaning Procedure StepSanitizing Procedure Removal of Parts for Cleaning or Sanitizing Dump Valve Removal Dump Valve DisassemblyWater Dump Valve Ice Thickness Probe Water PumpWater Pump Removal Ice Thickness Probe RemovalFloat Valve Removal Float ValveWater Distribution Tube Water Distribution Tube DisassemblyTube Water CurtainChecklist Section Before Calling for ServiceSection Before Calling for Service Safety Limit Feature Before Calling for Service SectionPage Manitowoc ICE, INC

Q 800 specifications

The Manitowoc Ice Q 800 is a state-of-the-art ice maker designed to meet the demands of the modern commercial kitchen. Renowned for its reliability, efficiency, and advanced features, the Q 800 stands out as a favored choice among establishments requiring high volumes of ice, such as restaurants, bars, hotels, and catering services.

One of the defining characteristics of the Manitowoc Ice Q 800 is its production capacity. Capable of producing up to 800 pounds of ice per day, this machine can handle the rigorous demands of a busy environment. Its production cycle is optimized to ensure a continuous supply of ice, minimizing downtime and ensuring that staff have constant access to the ice needed for drinks, food preservation, and other uses.

The Q 800 utilizes the innovative Manitowoc SmartClean technology, which significantly reduces the time and effort required for cleaning. This feature ensures that the interior components are maintained in prime condition, ultimately extending the lifespan of the machine. The automated cleaning system activates a deep-cleaning cycle that aids in bacteria control and ice quality, providing peace of mind for food safety.

Moreover, the unit incorporates an advanced air filtration system that minimizes dust and debris intake. This not only improves operational efficiency but also enhances ice quality by reducing contaminants. The air-cooled condenser system is designed for optimal energy efficiency, reducing electricity costs and contributing to a more sustainable operation.

The control panel of the Manitowoc Ice Q 800 is designed for intuitive use. With straightforward push-button controls, operators can easily adjust settings, initiate cleaning cycles, and monitor production and performance at a glance. Additionally, the machine features a durable and compact design, fitting snugly in most kitchen layouts while maintaining an easily accessible service area for maintenance.

With its combination of efficiency, advanced technology, and a user-friendly interface, the Manitowoc Ice Q 800 continues to uphold its reputation as a top-tier ice-making solution in the foodservice industry. Whether for creating refreshing beverages or chilling food, the Manitowoc Ice Q 800 is engineered to deliver superior performance for any commercial kitchen operation.