Grindmaster LCD-2R Water overheat, Leak, Inlet valve leak, Tank thermistor fail, Reset System

Page 11

“Engineer” Program Settings

TO BE PERFORMED BY A QUALIFIED SERVICE TECHNICIAN ONLY

Machine Fault Codes (cont.)

6: Water overheat

The thermistor has detected the water is too hot. The boiler element contactor may have failed short circuit. The machine may be running high Wattage Power with a preheater.

7: Leak

If the machine refills 15 times without a dispense the machine assumes a leak. A water outlet valve may be leaking.

8: Inlet valve leak

Not available with single inlet valve machines

9: Tank thermistor fail

The thermistor has failed open circuit, or connections from the thermistor to the PCB may have failed.

10: Reset System

The watchdog timer on the control chip has timed out, the machine needs a reset. (Turn machine off, wait 5 sec- onds, turn back on).

Programming Guide for Calibration of Mix Ratio (refer to Figure D)

1.The water dump valves are factory set to 60 ml/sec (2 fl-ounces per second). If adjustment is required, disconnect power to the machine and remove the left side access plate to gain access to the dump valves.

2.Using an appropriate hex key, turn the adjustment screw on each dump valve clockwise to fully close the adjustor (Do not force the adjustment as permanent damage can occur to the valve)

3.Turn each dump valve adjustor counter clockwise as indicated below to achieve

(2)fl-ounce per second.

Top valve =

Left dispense head= 5.5 turns out CCW

Figure D

Middle valve=

Middle dispense head= 4.5 turns out CCW

Bottom valve =

Right dispense head= 4.0 turns out CCW

4. Reassemble machine and power ON.

Page 11

Model LCD-2R and LCD-2A

 

 

Image 11
Contents Grindmaster Corporation Introduction User Replaceable Parts Model LCD-2R and LCD-2A Water hook-up InstallationWater Inlet Connection Figure B Backside of access panelTo flush dispense spouts How to Dispense a Cup of CoffeeOn models with manual dispense pull handle switches Bag-in-Box Hook-upUser Programming Instructions Engineer Mode Engineer Program SettingsMachine Fault Codes Inlet valve leak Reset SystemWater overheat LeakImportant Note Regarding Portion Override Button Programming Guide for Calibration of Mix RatioMix Ratio Calculation Programming Guide for Calibration of Mix Ratio WorksheetDispensed Water Dispensed ConcentrateFigure E Weekly Cleaning InstructionsPurging Machine of all Water for Shipment in Cold Areas Service and CleaningDraining the Tank Control Board Diagnostic LEDs Troubleshooting GuideMachine does not Power UP Problem/Cause RemedyWater Continues to Drip from Dispense Spout 21752/3&% Grindmaster Corporation Form # AM-328-04 63543