Frequently asked questions
What if... | Possible fault | Fix | ||
|
|
|
| |
. . . there is no prompt | The unit has no | Is the door closed? | ||
in the message | power. | Check that the circuit has not | ||
window? |
|
| tripped, the fuse has blown or | |
|
|
| that the appliance is unplugged. | |
|
|
| Otherwise contact the Miele | |
|
|
| Technical Service Department. | |
|
|
|
| |
. . . the light does not | – Is the door open? | If not, the light bulb has burned | ||
illuminate? | – Is the unit in | out. | ||
|
| standby mode? | See "Changing the light bulb". | |
| – Is the unit locked? |
| ||
|
|
|
| |
. . . nothing comes out | The steam nozzle is | Carefully poke the opening with | ||
of the steam nozzle? | clogged. | a thin, short needle or toothpick. | ||
|
|
|
| |
. . . the grinding is | There could be | Immediately turn off the unit. | ||
louder that normal? | pebbles among the | Call the Miele Technical Service | ||
| coffee beans. | Department. | ||
|
|
|
| |
. . . there is a low | The coffee bean | Wait until the sound stops. Refill | ||
grinding noise? | container is empty. A | the coffee bean container. | ||
| message appears in |
| ||
| the message window. |
| ||
|
|
|
| |
|
|
|
| |
|
|
|
| |
. . . the display shows | The grinder has | Turn the coffee system off and | ||
"Fill coff. beans | overheated. This | let the grinder cool. | ||
Ready for use" but | happens after |
| ||
there are still beans in | brewing 40 cups in |
| ||
the coffee bean | quick succession. |
| ||
container? |
|
|
| |
|
|
|
| |
. . . the unit suddenly | Is the door closed? | Close the door properly. | ||
turns off? |
|
|
| |
The water temp- | The unit stops until the water | |||
| ||||
| erature could be too | has cooled. | ||
| high. |
| ||
|
|
|
| |
| There could be stones | In this case the unit shuts off | ||
| in the coffee beans. | after 20 secs. to prevent | ||
|
|
| damage. Call Technical Service. | |
|
|
|
|
48