COMPONENT DESCRIPTION: Control Box

Circuit Board:

 

The circuit board receives

 

input signals from several

 

sensors and translates them to

 

control the electrical power

 

supply to the various loads.

 

The sensors include:

 

￿Touch Free ice or water.

 

￿Ice level in the bin.

 

￿Water level in the reservoir.

 

The loads include:

 

￿Compressor contactor

 

￿Fan motor

 

￿Bin drive motor

 

￿Auger drive motor

 

￿Water solenoid.

 

In addition, a “Clean” switch is

ON-OFF

available to temporarily disable

SWITCH

the Touch-Free sensors for

 

cleaning of the splash panel.

 

On/Off Switch: Manual

 

control for the machine.

 

Contactor: A definite purpose

 

contactor connecting the

 

compressor to the power

 

supply.

 

Potential Relay: The

 

compressor start relay.

 

START

CAPACITOR

CONTACTOR

POTENTIAL

RELAY

CIRCUIT BOARD

May 2001

Page 12

Image 12 Contents
Table of Contents IntroductionMDT5N25 & MDT5N40 For the Installer Environmental Limitations Installation Limitations Service LimitationsMinimum Maximum Water LimitationsFor the Installer Machine Stand InstallationCounter Top or Machine Stand Installation Unpack and install the ice and water spoutsFor the Installer Wall Mount Kit For the Plumber Conform to ALL Applicable CodesFor the Electrician For the Installer Final Check List Initial Start UP Pre Start InspectionStart Up Component Description ICE Sweep Bearing Breaker Motor Evaporator Auger Water Seal On/Off Switch Manual Component Description Control BoxCircuit Board Potential RelaySplash panel cleaning Electrical SequenceStart up consists Shut Down consistsOperation Water Refrigeration Schematic Operation RefrigerationOperation Ice Vending ContainerDispense Area Sanitation Cleaning and Sanitizing Scotsman Ice Machine Cleaner contains acidsTo Sanitize Check and tighten all bolts and screws Maintenance and Cleaning Moving Parts HazardService Diagnosis Symptom Possible Cause Probable CorrectionMDT5N25 & MDT5N40 Service Diagnosis Circuit Board PowerOff Timer Bin EmptyRemoval and Replacement BIN Controls Ice Level SensorsRemoval and Replacement Bearing And Breaker To Remove the Breaker Bearing AssemblyTo Remove the Auger Removal and Replacement Water Seal To Remove the Water SealTo Replace the Water Seal For Access to the Evaporator to Gearmotor bolts To Replace the EvaporatorTo Reassemble the Evaporator and Auger To Remove and Repair the Gearmotor Assembly Electrical Shock HazardTo Inspect the gearmotor Refrigeration Service R-404A HP62 Do not USE Mineral OIL in this Refrigeration SystemRefrigeration Service General InformationOnly a HFC type dryer should be used Circuit Board Service Printed Circuit Board Handling PrecautionsLiquid Charging Instructions for R-404A