MAINTENANCE AND CLEANING

In some areas, the water supply to the ice maker will contain a high concentration of minerals, and that will result in an evaporator and auger becoming coated with these minerals, requiring a more frequent removal than twice per year. If in doubt about the condition of the evaporator and auger, the auger can be removed so the parts can be inspected.

Moving Parts Hazard.

Disconnect electrical power to the icemaker - dispenser before beginning.

Note: Water filters can filter out suspended solids, but not dissolved solids. “Soft” water may not be the complete answer. Check with a water treatment specialist regarding water treatment.

For more information on removal of these parts, see REMOVAL AND REPLACEMENT.

1.To remove the auger, remove the front and top panels.

2.Push bail clamp off of cover and remove cover.

3.Unscrew and remove ice sweep.

4.Remove ice chute from evaporator.

5.Remove 4 allen screws holding breaker to evaporator.

6.Pull up to remove auger.

After the auger has been removed, allow the auger to dry: if the auger is not bright and shiny, it must be cleaned.

Clean the auger and evaporator as required. DO NOT HONE THE EVAPORATOR.

7.Replace the water seal.

8.Reverse to reassemble.

ALLEN

HEAD

SCREWS

BREAKER

AND AUGER

ASSEMBLY

May 2001

Page 20

Image 20 Contents
Table of Contents IntroductionMDT5N25 & MDT5N40 For the Installer Environmental Limitations Installation Limitations Service LimitationsMinimum Maximum Water LimitationsFor the Installer Machine Stand InstallationCounter Top or Machine Stand Installation Unpack and install the ice and water spoutsFor the Installer Wall Mount Kit For the Plumber Conform to ALL Applicable CodesFor the Electrician For the Installer Final Check List Start Up Initial Start UPPre Start Inspection Component Description ICE Sweep Bearing Breaker Motor Evaporator Auger Water Seal On/Off Switch Manual Component Description Control BoxCircuit Board Potential RelaySplash panel cleaning Electrical SequenceStart up consists Shut Down consistsOperation Water Refrigeration Schematic Operation RefrigerationOperation Ice Vending ContainerDispense Area Sanitation To Sanitize Cleaning and SanitizingScotsman Ice Machine Cleaner contains acids Check and tighten all bolts and screws Maintenance and Cleaning Moving Parts HazardService Diagnosis Symptom Possible Cause Probable CorrectionMDT5N25 & MDT5N40 Service Diagnosis Circuit Board PowerOff Timer Bin EmptyRemoval and Replacement BIN Controls Ice Level SensorsRemoval and Replacement Bearing And Breaker To Remove the Breaker Bearing AssemblyTo Remove the Auger To Replace the Water Seal Removal and Replacement Water SealTo Remove the Water Seal To Reassemble the Evaporator and Auger For Access to the Evaporator to Gearmotor boltsTo Replace the Evaporator To Inspect the gearmotor To Remove and Repair the Gearmotor AssemblyElectrical Shock Hazard Refrigeration Service R-404A HP62 Do not USE Mineral OIL in this Refrigeration SystemOnly a HFC type dryer should be used Refrigeration ServiceGeneral Information Circuit Board Service Printed Circuit Board Handling PrecautionsLiquid Charging Instructions for R-404A