Vulcan-Hart VC6EC, VCIEC Temp F Ohms, Amps PER Voltage KW PER Element Ohms PER Lead, 208 240 480

Page 20

FULL SIZE ELECTRIC CONVECTION OVENS - SERVICE PROCEDURES AND ADJUSTMENTS

TEMPERATURE PROBE TEST

 

HEATING ELEMENT TEST

(SOLID STATE CONTROL)

 

 

WARNING: DISCONNECT THE ELECTRICAL POWER TO THE MACHINE AT THE MAIN CIRCUIT BOX. PLACE A TAG ON THE CIRCUIT BOX INDICATING THE CIRCUIT IS BEING SERVICED.

NOTE: The temperature probe used in conjunction with the Solid State Temperature control is an RTD (resistance temperature detector) of the Thermistor type. As temperature increases the resistance value decreases.

1.Remove the right side panel as outlined under "COVERS AND PANELS" in "REMOVAL AND REPLACEMENT OF PARTS".

NOTE: If right side panel is not accessible, this component can be serviced by removing the control panel as outlined under "COVERS AND PANELS".

2.Place a shielded thermocouple in the geometric center of the oven cavity and determine the temperature in the oven cavity.

3.Remove the probe lead wires from the solid state temperature control.

4.Test the probe with an ohmmeter.

A.If the measured resistance values are inside the given tolerance then the probe is functioning properly.

B.If the measured resistance values are outside the given tolerance then replace the probe and retest.

1)Check oven for proper operation.

5.Reverse procedure to install.

TEMP (°F)

OHMS*

TEMP (°F)

OHMS*

 

 

 

 

77

90,000

360

822

 

 

 

 

240

4,077

380

656

 

 

 

 

260

3,016

400

529

 

 

 

 

280

2,266

425

424

 

 

 

 

300

1,726

450

334

 

 

 

 

320

1,332

475

266

 

 

 

 

340

1,041

 

 

 

 

 

 

(*) Resistance in ohms ± 10%

WARNING: THE FOLLOWING STEPS REQUIRE POWER TO BE APPLIED TO THE UNIT DURING THE TEST. USE EXTREME CAUTION AT ALL TIMES.

1.Turn the power switch ON and set the oven temperature control to the highest setting.

2.Measure the voltage at the heating element terminals and verify it against the data plate voltage.

A.If voltage is incorrect, find the source of the problem.

B.If voltage is correct, check current draw (amps) through the heating element lead wires.

NOTE: This method is preferred over a resistance check when a clamp on type amp meter is available.

1)If current draw is correct then heating element is functioning properly. See table below for proper values.

2)If current draw is not correct, turn the power switch OFF and disconnect the electrical supply to the oven.

a.Replace heating element then proceed to step 3.

C.If unable to check current draw, a resistance check may indicate a malfunctioning element.

1)Turn the power switch OFF and disconnect the electrical supply to the oven.

2)Remove the lead wires from the heating element and check resistance (ohms). See table below for proper values.

3.Check for proper operation.

 

 

 

AMPS PER

 

VOLTAGE

KW PER

ELEMENT

OHMS PER

ELEMENT

LEAD

ELEMENT

 

 

 

1 PH

3 PH

 

 

 

 

 

 

 

208

 

2

60

35

21

 

 

 

 

 

 

240

 

2

52

33

28

 

 

 

 

 

 

480

 

2

15

4

111

 

 

 

 

 

 

NOTES:

1.

Values in the table are nominal.

 

 

Tolerance is +5/-10%.

 

 

2.

Voltage values are @ 60HZ.

 

3.

Resistance values (ohms) are @

 

 

room temperature.

 

 

 

 

 

 

 

F25105 (December 2001)

 

Page 20 of 60

 

Image 20
Contents VC4E & VC6E Series VC4ED ShownTable of Contents Full Size Electric Convection Ovens General VC6ES VC6ED VC6EC SpecificationsVC4ES VC4ED VC4EC Removal and Replacement of Parts Covers and PanelsControl Panel Components Left Side PanelRemovable Components Covers and PanelsTemperature Probe Solid State Control Component Panel ComponentsFront Access Heating ElementsLeft Side Elements Shown Alternate AccessBlower and Motor Door Switch Service Procedures and AdjustmentsDoor Window Oven Doors and Bearings Independent DoorsAssembly Removal Oven Doors Simultaneous DoorsDoor Catch Roller Assembly Independent Doors DisassemblyAssembly Removal Mechanical KX ThermostatLamp Assembly High Limit ThermostatInterior Lights LampCooling FAN Service Procedures and Adjustments Solid State Temperature Control CalibrationMechanical KX Thermostat Calibration Temperature Probe Test Solid State Control Solid State Temperature Control TestTroubleshooting 208 240 480 Temp F OhmsAmps PER Voltage KW PER Element Ohms PER Lead Blower Adjustment Door Adjustment Door Catch Roller Adjustment Independent DoorsIntroduction Door Switch AdjustmentProcedure Operation Setup modeComputer Control Alternating on Menu Display Parameter DataProbe Test Solid State Relay TestComputer Control Temperature Calibration Computer Control Operational TestKEY Code CalyHEY Restore Factory Settings Electrical Operation Component FunctionSSR1 & SSR2 1CON & 2CONMechanical Temperature Control Component LocationFull Size Electric Convection Ovens Electrical Operation Full Size Electric Convection Ovens Electrical Operation VC4EC/6EC Plug, Socket and Components Cook & Hold Standard VC4ED, VC6ED with Solid State Temperature Control Sequence of OperationCook Cycle VC4ES, VC6ES with Mechanical KX ThermostatVC4EC, VC6EC Computer Control Timer Cycle, Cooking KX Thermostat or Solid State ControlCool Down Cycle KX Thermostat or Solid State Control Cool Down Cycle Temperature and Time Cycle CookingCook and Hold Cycle Schematics VC4ES, VC6ES with Mechanical KX ControlsVC4ES, VC6ES with Mechanical KX Controls VC4ED, VC6ED with Solid State Temperature Control VC4ED, VC6ED with Solid State Temperature Control Full Size Electric Convection Ovens Electrical Operation VC4EC, VC6EC Computer Control, 480V Roast & Hold Standard This page Purposely Left Blank Wiring Diagrams VC4ES, VC6ES with Mechanical KX ControlFull Size Electric Convection Ovens Electrical Operation VC4ES, VC6ES with Mechanical KX Control Full Size Electric Convection Ovens Electrical Operation VC4ED, VC6ED with Solid State Temperature Control Full Size Electric Convection Ovens Electrical Operation VC4ED, VC6ED with Solid State Temperature Control Full Size Electric Convection Ovens Electrical Operation Full Size Electric Convection Ovens Electrical Operation Full Size Electric Convection Ovens Electrical Operation VC4EC, VC6EC Computer Control, 480V Roast & Hold Standard Full Size Electric Convection Ovens Electrical Operation ALL Models TroubleshootingFull Size Electric Convection Ovens Troubleshooting Computer Control Models only Control Operational TestComputer Control Error CodesCode & Problem Probable Cause Solution T E S Condensed Spare Parts List Part Number Description VC4ES VC4ED VC4EC VC6ES VC6ED VC6EC