Vulcan-Hart VC6EC Computer Control Temperature Calibration, Computer Control Operational Test

Page 26

FULL SIZE ELECTRIC CONVECTION OVENS - SERVICE PROCEDURES AND ADJUSTMENTS

A.If voltage is correct, SSR is functioning properly.

B.If no voltage is present on the load side of SSR terminal 2, the SSR is not functioning properly.

7.Turn the power switch OFF.

WARNING: DISCONNECT THE ELECTRICAL POWER TO THE MACHINE AT THE MAIN CIRCUIT BOX. PLACE A TAG ON THE CIRCUIT BOX INDICATING THE CIRCUIT IS BEING SERVICED.

8.Replace the SSR and check for proper operation.

COMPUTER CONTROL

TEMPERATURE CALIBRATION

1.Place a thermocouple in the geometric center of the oven cavity.

2.Turn the power switch ON.

A.If the set point temperature is 350°F, proceed to step 4.

B.If the set point temperature is other than 350°F, proceed to step 3 to change the temperature.

3.Press the set key then temperature key to enter the temperature set mode.

A.The display will alternate between the term "StPt" (set point) and the current oven temperature setting.

B.Press the up or down arrow keys to make the proper selection.

C.Press the set key again to save the change and exit the temperature set mode.

4.Allow the oven temperature to stabilize (normally 3 cycles).

5.Compare the controls set point temperature to the thermocouple meter reading when the heat light goes out.

A.A temperature variance more than 5°F indicates an adjustment is needed.

1)To make the adjustment, proceed to step 6.

2)If temperature variance is less than 5°F, computer control is functioning properly.

6.Enter the setup mode as outlined in "SETUP MODE" under "COMPUTER CONTROL".

A.Advance through the menu until CAL1 (Calibration Offset) appears.

1)If the thermocouple reading is higher than set point temperature, press the down arrow key and enter a negative offset value that is equal to the number of degrees above the 5°F tolerance.

2)If the thermocouple reading is lower than set point temperature, press the up arrow key and enter a positive offset value that is equal to the number of degrees below the 5°F tolerance.

3)Exit the setup mode.

7.Allow the oven to cycle at least two times between adjustments.

A.If the temperature variance still differs more than 5°F from the set point, verify the correct calibration offset value was entered and retained.

1)Adjust the calibration offset value as outlined in step 6, until the cycling temperature is within tolerance.

B.If the above adjustment cannot be obtained:

C.Turn the power switch OFF.

WARNING: DISCONNECT THE ELECTRICAL POWER TO THE MACHINE AT THE MAIN CIRCUIT BOX. PLACE A TAG ON THE CIRCUIT BOX INDICATING THE CIRCUIT IS BEING SERVICED.

D.Replace the computer control and check for proper operation.

COMPUTER CONTROL

OPERATIONAL TEST

The computer controls "Calibration Mode" is used to manually test:

Outputs of the control

Keypad functionality

Verify display and LEDs functionality

Additionally, if a problem is encountered during the output test, a "Restore Factory Settings" option is available.

CAUTION: The calibration mode contains several adjustable parameters that must not be changed. For the "CALY" (Calibration) Parameter, the default data option selected must be "no".

F25105 (December 2001)

 

Page 26 of 60

 

Image 26
Contents VC4E & VC6E Series VC4ED ShownTable of Contents Full Size Electric Convection Ovens General VC6ES VC6ED VC6EC SpecificationsVC4ES VC4ED VC4EC Removal and Replacement of Parts Covers and PanelsRemovable Components Control Panel ComponentsLeft Side Panel Covers and PanelsTemperature Probe Solid State Control Component Panel ComponentsFront Access Heating ElementsLeft Side Elements Shown Alternate AccessBlower and Motor Door Switch Service Procedures and AdjustmentsDoor Window Oven Doors and Bearings Independent DoorsAssembly Removal Oven Doors Simultaneous DoorsAssembly Removal Door Catch Roller Assembly Independent DoorsDisassembly Mechanical KX ThermostatInterior Lights Lamp AssemblyHigh Limit Thermostat LampCooling FAN Service Procedures and Adjustments Solid State Temperature Control CalibrationMechanical KX Thermostat Calibration Temperature Probe Test Solid State Control Solid State Temperature Control TestTroubleshooting 208 240 480 Temp F OhmsAmps PER Voltage KW PER Element Ohms PER Lead Blower Adjustment Door Adjustment Door Catch Roller Adjustment Independent DoorsIntroduction Door Switch AdjustmentProcedure Operation Setup modeComputer Control Probe Test Alternating onMenu Display Parameter Data Solid State Relay TestComputer Control Temperature Calibration Computer Control Operational TestKEY Code CalyHEY Restore Factory Settings SSR1 & SSR2 Electrical OperationComponent Function 1CON & 2CONMechanical Temperature Control Component LocationFull Size Electric Convection Ovens Electrical Operation Full Size Electric Convection Ovens Electrical Operation VC4EC/6EC Plug, Socket and Components Cook & Hold Standard Cook Cycle VC4ED, VC6ED with Solid State Temperature ControlSequence of Operation VC4ES, VC6ES with Mechanical KX ThermostatVC4EC, VC6EC Computer Control Timer Cycle, Cooking KX Thermostat or Solid State ControlCool Down Cycle KX Thermostat or Solid State Control Cool Down Cycle Temperature and Time Cycle CookingCook and Hold Cycle Schematics VC4ES, VC6ES with Mechanical KX ControlsVC4ES, VC6ES with Mechanical KX Controls VC4ED, VC6ED with Solid State Temperature Control VC4ED, VC6ED with Solid State Temperature Control Full Size Electric Convection Ovens Electrical Operation VC4EC, VC6EC Computer Control, 480V Roast & Hold Standard This page Purposely Left Blank Wiring Diagrams VC4ES, VC6ES with Mechanical KX ControlFull Size Electric Convection Ovens Electrical Operation VC4ES, VC6ES with Mechanical KX Control Full Size Electric Convection Ovens Electrical Operation VC4ED, VC6ED with Solid State Temperature Control Full Size Electric Convection Ovens Electrical Operation VC4ED, VC6ED with Solid State Temperature Control Full Size Electric Convection Ovens Electrical Operation Full Size Electric Convection Ovens Electrical Operation Full Size Electric Convection Ovens Electrical Operation VC4EC, VC6EC Computer Control, 480V Roast & Hold Standard Full Size Electric Convection Ovens Electrical Operation ALL Models TroubleshootingFull Size Electric Convection Ovens Troubleshooting Computer Control Models only Control Operational TestComputer Control Error CodesCode & Problem Probable Cause Solution T E S Condensed Spare Parts List Part Number Description VC4ES VC4ED VC4EC VC6ES VC6ED VC6EC