Vulcan-Hart VCIEC, VC6ED, VC6EC, VC4ES, VC4ED, VC6ES Computer Control, Operation, Setup mode

Page 24

FULL SIZE ELECTRIC CONVECTION OVENS - SERVICE PROCEDURES AND ADJUSTMENTS

A.Turnbuckles should be 5 to 5 ½ inches apart.

B.Short eye bolt should be connected to the end of the chain that goes to the front of the sprocket.

C.2 links of the chain should not be engaged at the rear of the sprocket.

D.Chain must be tight enough that the doors move simultaneously when opened or closed.

E.When the doors are opened, the turnbuckles will move away from each other.

F.The stop cable must be positioned where it moves freely and does not get pinched.

3.Position door chain assembly to factory setting if the conditions in step 2 are not met.

B.If doors operate properly, continue to step 7.

7.Install the lower front cover.

COMPUTER CONTROL

Operation

Refer to the Instructions Manual for specific operating instructions.

Setup mode

NOTE: Use the setup mode to verify that the control is configured to the factory settings which result in the proper operation of the oven. If the CAL1 parameter is other than zero, determine if it is still needed before resetting to zero. See "COMPUTER CONTROL TEMPERATURE CALIBRATION".

CAUTION: Changing the C_F, InP1, rL1 & rH1 parameters will default all menus to the factory settings.

1.Use this key sequence to access the setup mode.

Up arrow; Rack 1; Temperature; Temperature; Down arrow; Rack 1

4.If right door does not lead the left door in closing:

A.Loosen locknuts on both turnbuckles.

B.Loosen left turnbuckle.

C.Tighten right turnbuckle.

D.Tighten locknuts on both turnbuckles.

5.If the right door leads the left door by more than 3/8 inch:

A.Loosen locknuts on both turnbuckles.

B.Loosen right turnbuckle.

C.Tighten left turnbuckle.

D.Tighten locknuts on both turnbuckles.

6.Check door for proper operation.

NOTE: The locknuts must be tight during testing or the adjustment will not hold.

A.If doors do not close properly, repeat step 4, 5 and 6.

2.Once in the setup mode the display will alternate between the parameter and programmed data.

To change data to the factory setting, use the arrow keys.

To select the next parameter, press the Rack 1 key.

After the last Parameter and Data is viewed, press the Rack 1 key a final time to exit the setup mode and return to operations mode. The current set point temperature will be displayed.

After 1 minute of no key activations, the control will return to operation mode.

3.Listed are the parameters and data you should find.

F25105 (December 2001)

 

Page 24 of 60

 

Image 24
Contents VC4E & VC6E Series VC4ED ShownTable of Contents Full Size Electric Convection Ovens General Specifications VC4ES VC4ED VC4ECVC6ES VC6ED VC6EC Removal and Replacement of Parts Covers and PanelsControl Panel Components Left Side PanelRemovable Components Covers and PanelsTemperature Probe Solid State Control Component Panel ComponentsFront Access Heating ElementsAlternate Access Blower and MotorLeft Side Elements Shown Door Switch Service Procedures and AdjustmentsDoor Window Oven Doors and Bearings Independent DoorsAssembly Removal Oven Doors Simultaneous DoorsDoor Catch Roller Assembly Independent Doors DisassemblyAssembly Removal Mechanical KX ThermostatLamp Assembly High Limit ThermostatInterior Lights LampCooling FAN Service Procedures and Adjustments Solid State Temperature Control CalibrationMechanical KX Thermostat Calibration Solid State Temperature Control Test TroubleshootingTemperature Probe Test Solid State Control Temp F Ohms Amps PER Voltage KW PER Element Ohms PER Lead208 240 480 Blower Adjustment Door Adjustment Door Catch Roller Adjustment Independent DoorsDoor Switch Adjustment ProcedureIntroduction Setup mode Computer ControlOperation Alternating on Menu Display Parameter DataProbe Test Solid State Relay TestComputer Control Temperature Calibration Computer Control Operational TestCaly HEYKEY Code Restore Factory Settings Electrical Operation Component FunctionSSR1 & SSR2 1CON & 2CONMechanical Temperature Control Component LocationFull Size Electric Convection Ovens Electrical Operation Full Size Electric Convection Ovens Electrical Operation VC4EC/6EC Plug, Socket and Components Cook & Hold Standard VC4ED, VC6ED with Solid State Temperature Control Sequence of OperationCook Cycle VC4ES, VC6ES with Mechanical KX ThermostatTimer Cycle, Cooking KX Thermostat or Solid State Control Cool Down Cycle KX Thermostat or Solid State ControlVC4EC, VC6EC Computer Control Temperature and Time Cycle Cooking Cook and Hold CycleCool Down Cycle Schematics VC4ES, VC6ES with Mechanical KX ControlsVC4ES, VC6ES with Mechanical KX Controls VC4ED, VC6ED with Solid State Temperature Control VC4ED, VC6ED with Solid State Temperature Control Full Size Electric Convection Ovens Electrical Operation VC4EC, VC6EC Computer Control, 480V Roast & Hold Standard This page Purposely Left Blank Wiring Diagrams VC4ES, VC6ES with Mechanical KX ControlFull Size Electric Convection Ovens Electrical Operation VC4ES, VC6ES with Mechanical KX Control Full Size Electric Convection Ovens Electrical Operation VC4ED, VC6ED with Solid State Temperature Control Full Size Electric Convection Ovens Electrical Operation VC4ED, VC6ED with Solid State Temperature Control Full Size Electric Convection Ovens Electrical Operation Full Size Electric Convection Ovens Electrical Operation Full Size Electric Convection Ovens Electrical Operation VC4EC, VC6EC Computer Control, 480V Roast & Hold Standard Full Size Electric Convection Ovens Electrical Operation Troubleshooting Full Size Electric Convection Ovens TroubleshootingALL Models Computer Control Models only Control Operational TestError Codes Code & Problem Probable Cause SolutionComputer Control T E S Condensed Spare Parts List Part Number Description VC4ES VC4ED VC4EC VC6ES VC6ED VC6EC