•Calibration Error, Clean out hopper and check calibration: This alarm indicates that the maximum empty weight for the weigh hopper has been exceeded. The blender will automatically tare up to 0.25 lbs of material, but if this weight is exceeded, then an alarm will appear. This alarm is most commonly caused by a build up of sticky material in the weigh hopper and can be corrected by simply cleaning out the weigh hopper. If this does not correct the problem, then the scale calibration should be checked by maintenance.
CALIBRATION ERROR
Clean out hopper and
check calibration
•Power Interruption while metering a Batch: This alarm indicates that the blender’s power was turned off while the blender was making a batch. The batch accuracy is not effected as long as the blender is configured for “AutoStart.” The blender will finish the last batch accurately even if the material was dumped into the mixer when the power was turned off.
POWER INTERRUPTION
While metering a
Batch
•PLC Battery Low: PLC battery is low and may cause the blender to lose both the program and the blender configuration. Notify Maintenance immediately.
PLC BATTERY LOW
•Inventory Cleared: This is only logged in the Alarm Log and does not cause a
Page 64 of 118 | SGB Batch Blender with Mitsubishi Controller |