Contents
Operation Maintenance
Read these carefully
Contents
About this manual
General Information
Literature change
Unit Nameplate
CVHF091NAL00ACU2758W7E8TB
C0000000K01G14C10W1A03B1
Commonly Used Acronyms
Control Optional Packages
Overview
Cvhf
General Information
General Information
Cooling Cycle
Cvhf Compressor
CVHE, Cvhg pressure enthalpy curve
Cvhf pressure enthalpy curve
TechView Chiller Service Tool
DynaView Human Interface
CVHE, CVHF, and Cvhg sequence of operation running
General Information
Surface Temperatures
Oil and Refrigeration Pump
Oil refrigerant pump
Base Loading Control Algorithm
20 100 percent RLA
General Information
Ice Machine Control
Free Cooling Cycle
Free Cooling Frcl
Hot Gas Bypass
Hot Water control
Heat Recovery Cycle
Auxiliary Condensers
Unit Control Panel UCP
Unit Control Panel UCP
Control Panel Devices and Unit Mounted Devices
Variable water flow through the evaporator
User-defined language support
Operator Interface
DynaView main processor
Operator Interface
Chiller Stop Prevention/Inhibit Feature
How It Works
Top Level Mode Description
System Reset
Minsec
Reference
Main Screen
Diagnostic Screen
Back button provides navigation back to the chiller screen
Operator Interface
Reports Evaporator Report items Units
Condenser Report Items Units
RPM
Compressor Report Items Units
Motor Report Items Units
Purge Report Items Units
RLA
Historic Diagnostics Log
Ashrae Chiller Log Units
PPM
Chilled Water Setpoint
Description Units Default Monitor Value
Feature Settings
Mode Overrides
Chiller
Purge
Description Units Default
Display Settings
Operator Interface
Operator Interface
Operator Interface
Operator Interface
Operator Interface
IPC3 Definitions Bus Management
Interprocessor Communication
Inter Processor Communications IPC3
Binding
Control panel components layout and approximate dimensions
Control System Components
Control System Components
Control Panel Devices
Compressor Running Relay
Machine Shutdown Manual Reset MMR
Head Relief Request Output
Opst
Refrigerant Monitor Input 1A17
Exop
Trmm TRM4 Tracer Comm 4 interface
Frcl Free Cooling Option
Hgbp Hot Gas Bypass Option
Cdrp Condenser Refrigerant Pressure Output
Pressure based
Temperature based
Condenser Pressure Output
Refrigerant Differential Pressure Indication Output
Percent RLA Output
Gbas Generic Building Automation System
Gbas
External Current Limit Setpoint
Module Characteristics
External Chilled Water Setpoint Ecws
Wpsr WFC Water Pressure Sensing Option
1A14 Communication interface Module
1A8, 1A9, 1A11, 1A12 Quad Relay Output Status
1A13, 1A18, 1A19, 1A20 Dual Binary input module
Comm +
Analog Input
Recommended Length to Run external Output signals
1A15, 1A16, 1A17, 1A21 Dual Analog Input/output Module
Unit mounted devices
UCP and Wye-Delta Starter Control Circuits
Control Sequence of Operation
Electrical Sequence
Delay time 200 msec. Opens 2K1
Control Sequence of Operation
Test and start timing sequence
AFD
Momentary Power Loss MPL Protection
Machine Protection Adaptive Control
Current Overload Protection
Overload trip time versus percent RLA
Reverse Rotation Protection
Phase Loss Protection
Current Limit Protection
Minimum and Maximum Capacity Limit
Differential to Start or Stop
SoftLoading
Leaving Water Temperature Cutout
Evaporator Limit
Low Refrigerant Temperature Cutout
Main Processor Software Revision 6.0 and higher
Cutout strategy
Evaporator Variable Flow Compensation
Condenser Limit
Restart Inhibit Free Starts
Restart Inhibit Start to Start Time Setting
Restart Inhibit
Clear Restart Inhibit
High Vacuum Lockout
Oil Temperature Control
Maximum Reset
Controls Chilled Water Reset CWR
Outdoor Air Temperature
Return Water
Constant Return
Values for start reset types
Degrees of Reset
Equation
Reset Ratio
Outdoor air temperature versus degrees of reset
Reset function for return CWR
Reset Ratio = 50%
Return CWR
Daily Unit Start-Up
Unit Start-Up Procedures
Unit Startup
Toxic Hazards
Before changeover to heating mode
Live Electrical Components
Seasonal Unit Start-Up
Oil Pump Heater Operation
Unit Shutdown Procedures
Unit Shutdown
Seasonal Unit Shutdown
Moisture Contamination
Periodic Maintenance
Daily Maintenance and Checks
Record Keeping Forms
Hazardous Voltage w/ Capacitors
Weekly Maintenance
Normal Chiller Operating Characteristics
Every 3 Months
Off-Season Maintenance
Annual Maintenance
Heater Damage
Oil Maintenance
Oil Change Procedure
Compressor Oil Change on
Oil Filter Replacement
Replacing Oil Filter
Other Maintenance Requirements
Maintenance
Oil Supply System Problems
Lubrication
Do not Leave Grease Fittings Installed
Front View with Refrigerant Pump
Contains Refrigerant
Refrigerant Charge
Cleaning the Condenser
Recovery and Recycle Connections
Leak Testing
Proper Water Treatment
Unit Corrosion Damage
Cleaning the Evaporator
Control Settings Adjustments
Purge System
Unit Preparation
Hazardous Voltage w/ Capacitors
100
101
102
103
104
105
106
107
108
109
110
111
Trane