GE JVM2070_H Primary Interlock System Test, Interlocks Door Latch Switches, Door Sensing Switch

Page 17
Interlocks (Door Latch Switches)

Using a small screwdriver, release the tab and remove the door interlock switch from the door switch bracket. Disconnect the electrical connector.

Interlocks (Door Latch Switches)

Interlocks are designed as follows:

Primary Interlock System Test

WARNING: Disconnect the oven from the power supply.

Door Sensing Switch

Isolate the switch and connect the ohmmeter to the common (COM.) and normally open (NO) terminal of the switch. The meter should indicate an open circuit with the door open and a closed circuit with the door closed.

Power Relay

Disconnect 2 wires from the tab terminals on the circuit board provided in the control panel assembly. The tab terminals are located in the area of the circuit board on the component side, and are connected to the contacts of the power relay. Check the state of the relay contacts using an ohmmeter. The relay contacts should be open. If the relay contacts are closed, replace the circuit board.

Primary Interlock Switch Test

Isolate the switch and connect the ohmmeter to the common (COM.) and normally open (NO) terminal of the switch. The meter should indicate an open circuit with the door open and a closed circuit with the door closed. If improper operation is indicated, replace the primary interlock switch.

Note: The primary interlock switches are not adjustable and must be replaced if test is failed.

Primary Interlock System TestDoor Sensing Switch (top)

Door Sensing Switch Monitor Interlock Switch (middle)

Power RelayPrimary Interlock Switch (bottom)

Door Sensing Switch:

Door Closed - 0 ohms

Door Open - Infinite ohms

Monitor Interlock Switch:

Door Closed - Infinite ohms

Door Open - 0 ohms

Primary Interlock Switch:

Door Closed - 0 ohms

Door Open - Infinite ohms

Note: Remove the wires from the switches before checking continuity.

– 17 –

Image 17
Contents 2/04 PUB #TECHNICAL SERVICE GUIDE Over the Range Microwave Oven MODEL SERIES JVM2070HTechnical Service Guide Copyright IMPORTANT SAFETY NOTICERECONNECT ALL GROUNDING DEVICES GE Consumer & IndustrialA. DO NOT OPERATE OR ALLOW THE OVEN TO BE OPERATED WITH THE DOOR OPEN Table of Contents Feature Pack InstallationNomenclature Model NumberTouchscreen Display Control FeaturesHELP HOMETop View Component Locator Views1 - Magnetron 2 - Magnetron Thermal Cutout TCO Right Side View3 - High Voltage Transformer 4 - Magnetron Cooling Fan Motor and Blade 5 - High Voltage CapacitorComponents Microwave Removal and Component AccessExhaust Fan RemovalSide Stirrer Side Stirrer MotorTop Stirrer Top Stirrer MotorCooling Fan and Motor Fuses Cavity Thermal Cutout TCOMagnetron Thermal Cutout TCO Transformer MagnetronGas Sensor Interior Light Hidden Vent MotorDoor Sensing and Primary Interlock Switches Door Interlock SwitchesMonitor Switch Control PanelDoor Sensing Switch Interlocks Door Latch SwitchesPower Relay Primary Interlock Switch TestHigh Voltage Capacitor Removal and ReplacementBottom and Hood Thermal Cutout TCO Turntable MotorSurface Lamps Surface Lamp AssembliesSensor Test Quick Test TroubleshootingControl Performance Test Error Message Diagnostics TestDemonstration Mode Displayed InformationHigh Voltage Capacitor Microwave Leakage TestPerformance Test CN03 - Vent Blower Connector CN01 - Ribbon connectorCN04 - Cooktop Lamp Relay Connector CN06 - Door Sensing ConnectorFan Motor Does Not Work Strip CircuitsLouver Motor Does Not Work Vent Motor Does Not Work Dead Unit - Cavity or Magnetron TCO Does Not Work Top Stirrer, Side Stirrer, or Drive Motor Does Not WorkDead Unit - Bottom TCO Does Not Work FAN MOTORInterior Light Does Not Work Surface Lamps Do Not Work 2 - White Magnetron Does Not Work3 - Blue BlackWARNING Power must be disconnected before servicing this appliance Wiring DiagramCode No. DE99-00125F SchematicIllustrated Parts Catalog CATALOG NUMBER VIEW NUMBERDESCRIPTION QUANTITYPLATE MOUNTING ASM For the period of WarrantyGE will replace Full one-year