Magnetron Does Not Work

Magnetron Does Not Work

Does continuity exist between the HV

transformer black wire and power cord with primary interlock closed (door closed)?

Yes

Does continuity exist between the HV

transformer blue wire and secondary interlock-2

blue wire thru HV transformer fuse?

Yes

Does continuity exist between the secondary

interlock-2 blue wire and power cord?

Yes

Does continuity exist between the HV transformer white wire to power cord thru secondary interlock - 1 (door closed) and monitor interlock switch open (door closed)?

Yes

Replace the main control board.

Does the magnetron work?

No

Replace the HV capacitor.

Does the magnetron work?

No

Replace the HV transformer.

Does the magnetron work?

No

Replace the magnetron.

Replace the primary interlock switch or repair

No 2 - White faulty wiring between the HV transformer and the primary interlock switch.

No

 

Replace the HV transformer fuse or

 

repair faulty wiring.

No

Repair faulty wiring.

No

Repair faulty wiring.

 

1

1

- Red

 

2

2 - White

3 - Blue

4

- Black

2

3

4

– 27 –

Image 27
Contents Over the Range Microwave Oven MODEL SERIES JVM2070H PUB #2/04 TECHNICAL SERVICE GUIDEGE Consumer & Industrial IMPORTANT SAFETY NOTICETechnical Service Guide Copyright RECONNECT ALL GROUNDING DEVICESA. DO NOT OPERATE OR ALLOW THE OVEN TO BE OPERATED WITH THE DOOR OPEN Table of Contents Model Number InstallationFeature Pack NomenclatureHOME Control FeaturesTouchscreen Display HELPTop View Component Locator Views4 - Magnetron Cooling Fan Motor and Blade 5 - High Voltage Capacitor Right Side View1 - Magnetron 2 - Magnetron Thermal Cutout TCO 3 - High Voltage TransformerRemoval Microwave Removal and Component AccessComponents Exhaust FanSide Stirrer Side Stirrer MotorTop Stirrer Top Stirrer MotorCooling Fan and Motor Cavity Thermal Cutout TCO Magnetron Thermal Cutout TCOFuses Magnetron Gas SensorTransformer Interior Light Hidden Vent MotorControl Panel Door Interlock SwitchesDoor Sensing and Primary Interlock Switches Monitor SwitchPrimary Interlock Switch Test Interlocks Door Latch SwitchesDoor Sensing Switch Power RelayTurntable Motor Removal and ReplacementHigh Voltage Capacitor Bottom and Hood Thermal Cutout TCOSurface Lamps Surface Lamp AssembliesTroubleshooting Control Performance TestSensor Test Quick Test Displayed Information Diagnostics TestError Message Demonstration ModeMicrowave Leakage Test Performance TestHigh Voltage Capacitor CN06 - Door Sensing Connector CN01 - Ribbon connectorCN03 - Vent Blower Connector CN04 - Cooktop Lamp Relay ConnectorStrip Circuits Louver Motor Does Not Work Vent Motor Does Not WorkFan Motor Does Not Work FAN MOTOR Top Stirrer, Side Stirrer, or Drive Motor Does Not WorkDead Unit - Cavity or Magnetron TCO Does Not Work Dead Unit - Bottom TCO Does Not WorkInterior Light Does Not Work Surface Lamps Do Not Work Black Magnetron Does Not Work2 - White 3 - BlueWARNING Power must be disconnected before servicing this appliance Wiring DiagramCode No. DE99-00125F SchematicIllustrated Parts Catalog QUANTITY VIEW NUMBERCATALOG NUMBER DESCRIPTIONPLATE MOUNTING ASM Full one-year WarrantyFor the period of GE will replace