GE JVM2070_H manual Diagnostics Test, Demonstration Mode, Displayed Information, Error Message

Page 21
Diagnostics Test

Diagnostics Test

Simultaneously press the LIGHT and OFF keys for 3 seconds. The diagnostics screen will appear in the LCD display.

Sample Diagnostics Screen

Displayed Information

MODEL - Identified at power-up by the keytail ID option.

CODE VERSION - The date the code file was sent to GEA for testing (MM-DD-YY).

HUMIDITY SENSOR - The CUR (current), DET (detection point), MIN (minimum), MAX (maximum) humidity sensor data will update continuously.

The CUR value is the present A/D value of the sensor. DET is the value at the moment the humidity detection point was reached. MIN is the lowest humidity point measured during entire feature’s run. MAX is the highest humidity value measured during the feature’s run. These data points are the dynamic measurements of the sensor, not the calculated values.

Pressing the DONE key terminates the diagnostic screen. The screen returns to the previous or HOME screen. The diagnostic screen will timeout and return to the previous screen after receiving no input for 5 minutes.

Error Message

F1 Convection - Open thermal sensor

F2 Convection - Shorted thermal sensor

F3 - Keypanel shorted for more than 60 seconds

F4 - Open humidity sensor

F5 - Shorted humidity sensor

F10 - Shorted touch panel

Note: Any “F” code will cause an error sound to beep for 3 cycles. One cycle will sound 2 seconds on, 1 second off.

Sample “F” Code page

Demonstration Mode

In demonstration mode, everything will operate on the unit except the high voltage section.

To enter the demonstration mode, disconnect the power for 30 seconds then reapply power. Simultaneously press the HELP screen pad and the BOOST button for 3 seconds. The word DEMO will appear in the LCD display.

To exit the demonstration mode, disconnect the power for 30 seconds then reapply power.

– 21 –

Image 21
Contents 2/04 PUB #TECHNICAL SERVICE GUIDE Over the Range Microwave Oven MODEL SERIES JVM2070HTechnical Service Guide Copyright IMPORTANT SAFETY NOTICERECONNECT ALL GROUNDING DEVICES GE Consumer & IndustrialA. DO NOT OPERATE OR ALLOW THE OVEN TO BE OPERATED WITH THE DOOR OPEN Table of Contents Feature Pack InstallationNomenclature Model NumberTouchscreen Display Control FeaturesHELP HOMETop View Component Locator Views1 - Magnetron 2 - Magnetron Thermal Cutout TCO Right Side View3 - High Voltage Transformer 4 - Magnetron Cooling Fan Motor and Blade 5 - High Voltage CapacitorComponents Microwave Removal and Component AccessExhaust Fan RemovalSide Stirrer Side Stirrer MotorTop Stirrer Top Stirrer MotorCooling Fan and Motor Cavity Thermal Cutout TCO Magnetron Thermal Cutout TCOFuses Magnetron Gas SensorTransformer Interior Light Hidden Vent MotorDoor Sensing and Primary Interlock Switches Door Interlock SwitchesMonitor Switch Control PanelDoor Sensing Switch Interlocks Door Latch SwitchesPower Relay Primary Interlock Switch TestHigh Voltage Capacitor Removal and ReplacementBottom and Hood Thermal Cutout TCO Turntable MotorSurface Lamps Surface Lamp AssembliesTroubleshooting Control Performance TestSensor Test Quick Test Error Message Diagnostics TestDemonstration Mode Displayed InformationMicrowave Leakage Test Performance TestHigh Voltage Capacitor CN03 - Vent Blower Connector CN01 - Ribbon connectorCN04 - Cooktop Lamp Relay Connector CN06 - Door Sensing ConnectorStrip Circuits Louver Motor Does Not Work Vent Motor Does Not WorkFan Motor Does Not Work Dead Unit - Cavity or Magnetron TCO Does Not Work Top Stirrer, Side Stirrer, or Drive Motor Does Not WorkDead Unit - Bottom TCO Does Not Work FAN MOTORInterior Light Does Not Work Surface Lamps Do Not Work 2 - White Magnetron Does Not Work3 - Blue BlackWARNING Power must be disconnected before servicing this appliance Wiring DiagramCode No. DE99-00125F SchematicIllustrated Parts Catalog CATALOG NUMBER VIEW NUMBERDESCRIPTION QUANTITYPLATE MOUNTING ASM For the period of WarrantyGE will replace Full one-year