GE 500A200P047 BUILT-IN Dishwasher Installation Instructions, Materials YOU will Need

Page 15

BUILT-IN DISHWASHER

INSTALLATION INSTRUCTIONS

ALL ROUGH-IN PLUMBING AND ELECTRICAL MUST BE COMPLETED

BEFORE THE DISHWASHER IS PLACED IN THE UNDERCOUNTER OPENING

ALL ELECTRICAL AND PLUMBING WORK MUST BE IN ACCORDANCE WITH LOCAL CODES

DISHWASHER SHOULD NOT BE INSTALLED IN AREA WHERE FREEZING OF WATER MAY OCCUR

WARNING

TO REDUCE THE RISK OF ELECTRIC SHOCK, FIRE, OR INJURY TO PERSONS, THE INSTALLER MUST ENSURE THAT THE DISHWASHER IS COMPLETELY ENCLOSED AT THE TIME OF INSTALLATION.

MATERIALS YOU WILL NEED

Dishwasher

Materials required:

G 90¡ elbow

(3/8Ó NPT external thread on one end and opposite end sized to fit water supply)

G Thread seal tape G Wire nuts (2)

For new installations only:

G Waste tee for house plumbing, if applicable G Electrical cable or power cord, if applicable G Screw type hose clamps

G Strain relief for electrical connection G Hand shut-off valve (optional)

G Water line 3/8Ó min. copper or 1/2Ó min. plastic

Electrical Cable or

90° Elbow

Screw Type Clamps

Power Cord

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Strain Relief

Thread Seal Tape

Wire Nuts

Waste Tee

Hot Water Line

Wire Nuts

Safe

PREPARE DISHWASHER ENCLOSURE

(For Undersink Dishwasher - see page 26)

¥The touch cabinet opening must have a minimum width of 24Ó, and a minimum of 34Ó high from floor to underside of the countertop. Figure A

¥The back wall should be free of pipes or wires. Figure A

¥Adjacent cabinets should be square and plumb to ensure a good fit. Figure A

¥For corner installation, allow 2Ó min. clearance between dishwasher and adjacent cabinet or wall or other appliances. Figure B

Countertop

34-1/2"±1/4" Underside of Countertop to Floor

 

This Wall Area

 

 

 

 

must be Free of

 

 

 

Pipes or wires

 

24"

 

 

 

 

 

5"

4"

5"

Min.

 

4"

 

 

 

 

 

 

 

 

Plumbing and Electric Service

 

 

Must Enter Inside This Area

 

 

 

 

 

6"

Cabinets Square

 

 

 

and Plumb

 

24"

 

 

 

 

Min.

 

 

 

Installation

Dishwasher

Clearance for Door Opening 2" Minimum

 

 

 

 

 

¥ Make sure the floor is level inside the opening and even

 

 

 

 

 

with the finished floor of the kitchen.

 

 

 

 

 

¥ The dishwasher must be installed no more than 10 feet

 

 

 

 

 

from sink for proper drainage.

 

 

 

 

 

 

25"

 

 

¥ This dishwasher must be fully enclosed on the top, sides

 

 

 

 

 

and back.

 

 

 

 

 

 

 

 

 

 

¥ The dishwasher must not support any part of the

 

 

 

 

 

 

 

 

 

 

enclosure.

Instructions

15

Image 15
Contents Use and Care Guide If you received a damaged dishwasher… To minimize the possibility of injury Important Safety InstructionsRead all instructions before using this appliance Important Safety InstructionsHOW to USE the Unicouple Connect Electricity HOW to Connect ElectricityElectrical requirements How to Connect Unicouple How toHOW to Operate Your Dishwasher Models With DelayModels Without Delay Instructions HOW to GET Started 3 Easy StepsHow to fill the rinse agent dispenser How to Test Water TemperatureHow to Use a Rinse Agent To get dishes clean and dry you need hot waterDetergents How to Choose and Use the Right DetergentHot Water Loading Detergent Rinse AgentsLower Rack HOW to Load Your DishwasherPlace settings Upper RackDonÕt let any item extend through bottom Wash TowerSilverware Baskets Keep the center area clear in the lower rack¥ GPF325A Almond ¥ GPF325B Black ¥ GPF325W White About Optional AccessoriesDescriptions of Optional Accessories Conversion KitCare of the Dishwasher Top Care and CleaningCare & Cleaning of the Dishwasher Before using, wipe well with a dry cloth toWhat YOU can Usually Wash Safely Your Dishwasher YESGlass YES Materials YOU will Need BUILT-IN Dishwasher Installation InstructionsFollow local codes and ordinances Prepare Drain PlumbingDo not install receptacle in cabinet opening for dishwasher Prepare Electrical WiringInstallation Dishwasher Sold With Power CordFigure H Remove access panel and toekick Remove leveling legs and wood base Install Leveling legsPosition dishwasher and fasten to cabinet Position water line and power supplyAlign water and electrical lines Level dishwasherFollow all local codes and ordinances InstallerOxidant compound and aluminum-to-copper connectors Connect drain lineDishwasher wet test check list Pre-test check list „ Check to be sure power is offReplace access panel and toekick „ Turn on water supplyQUESTIONS? USE this Problem Solver To remove stubborn spots and film from glassware Problem SolverTUB Problem Possible Cause Small Amount of WaterStanding in the Bottom TUB Water Wonõt Pump OUTProblem Solver Camco Service Camco ServicePrepare Enclosure for AN Undersink Dishwasher To continue installation go to

500A200P047 specifications

The GE 500A200P047 is a notable component within General Electric's extensive portfolio of innovative technologies. Widely recognized for its robust design and high performance, this device plays a pivotal role in various applications, particularly in industrial automation and power systems.

One of the standout features of the GE 500A200P047 is its exceptional reliability. Engineered for demanding environments, it is built to withstand extreme temperatures, vibrations, and other challenging conditions that are common in industrial settings. This reliability ensures that the component maintains optimal performance over time, reducing downtime and maintenance costs for operators.

The GE 500A200P047 also incorporates state-of-the-art technology aimed at enhancing efficiency and functionality. It features advanced digital controls, which allow for precise monitoring and management of electrical systems. This technological integration not only optimizes power distribution but also contributes to energy savings, making it an eco-friendly choice for enterprises looking to reduce their carbon footprint.

Furthermore, this component is designed with versatility in mind. It supports a range of applications, from low-voltage distributions to high-power industrial machinery. This adaptability makes the GE 500A200P047 a preferred choice among engineers and designers who require flexibility in their designs while ensuring top-tier performance.

Another notable characteristic of the GE 500A200P047 is its user-friendly interface. The design includes intuitive controls and diagnostic tools, facilitating easier operation and troubleshooting. This user-centric approach simplifies the complexity often associated with industrial systems, enabling quicker resolution of issues and enhancing overall productivity.

In terms of safety, the GE 500A200P047 is equipped with multiple safety features designed to protect both the system and its operators. These safety technologies prevent overload, short circuits, and other hazardous conditions, ensuring that operations run smoothly and securely.

In conclusion, the GE 500A200P047 stands out as a powerhouse in the industrial technology sector. With its impressive reliability, advanced digital controls, versatility, user-friendly interface, and robust safety features, it serves as a crucial component in modern industrial networks. Organizations looking to enhance efficiency and reliability in their operations will find the GE 500A200P047 to be an invaluable addition to their technological arsenal.