Fisher & Paykel DD90SDF(H)TX2, DD90SDFTM2 manual Min mm ventilation gap

Page 9

6b

INTEGRATED MODELS WITH BADGE (GB IE) ONLY - CUSTOM FRONT PANEL CALCULATIONS

9

 

 

FRONT PANEL SPECIFICATIONS

16 -20 mm panel thickness

Adequately sealed to withstand moisture (50OC @ 80% RH) Maximum weight of panel: 9 kg

The following calculations assume the top of the panel is aligned with the top of the adjacent cabinetry:

min. 2mm

WIDTH OF THE PANEL

Measure A (the width between adjacent door/drawer fronts) and write it in the first box below, then complete the equation.

 

 

 

 

clearance to

WIDTH OF PANEL

 

A

adjacent cabinet

 

front (min. 2 mm)

 

(min. 855 mm)

 

 

-

2x

 

 

=

 

 

 

 

 

 

 

 

 

 

 

HEIGHT OF THE PANEL

Measure B and write it in the first box below, then complete the equation.

ventilation gap

HEIGHT OF PANEL

B(min. 8 mm)

-

 

=

min. 2mm

B

A

WIDTH OF PANEL

HEIGHT

OF PANEL

min. 2mm

min. 2mm

min. 8 mm ventilation gap

Note: when the top of the dishwasher has to be lower than the adjacent cabinetry, the panel can be increased in height.

min. 8 mm ventilation gap

Image 9
Contents Installation Instructions DD90SDFHTX2 DD90SDFTM2 Follow the Installation Sequence Relevant to Your Model2b Additional Safety and Warnings Integrated Models only 2a Safety and Warnings ALL ModelsOptional 3a Parts Supplied ALL ModelsAttached to product 3b Additional Parts Supplied with Integrated ModelsPlan Product DimensionsCabinetry dimensions mm Cabinetry DimensionsFront Panel Specifications Min mm ventilation gap Water Connection 7a Cavity PreparationShelf cutouts Left hand side Maximum Distance of Hoses & Cord from Chassis EdgePage 9a Attach Side Mounting Brackets NOW Choose Which Installation Method a or b12a Secure the Drawer 11a Pull Through Hoses & Move Into the Cavity10b Pull Through Hoses & Move Into the Cavity 9b Integrated Models with Remote NZ AU only13b Refit the Drawer Onto the Runners 11b Remove the Drawer 12b Secure the Drawer to the CabinetryX14 17a Earth the Panel 18a Attach Panel to Product Badge zone When refitting Adjust Panel Height to Align the Cabinetry Gaps To required height Connect Inlet Hose to Cold Water 24 Plug ProductTroubleshooting Final Checklist