Fisher & Paykel DD90SDF(H)TX2 manual 11b Remove the Drawer 12b Secure the Drawer to the Cabinetry

Page 17

11b REMOVE THE DRAWER

12b SECURE THE DRAWER TO THE CABINETRY

17

 

1

Product may

move. Mark

chassis position on cavity

4

The product has three pairs of fixing points:

To prevent kinked hoses, we recommend rotating the drawer anti-clockwise and resting it on its side

after removal.

Ensure the sound insulation is repositioned correctly.

a pair of fixing holes either side on the bottom

1

2

 

 

100

mm

 

 

 

Press the release tabs

 

 

5

 

 

 

in on either side and

 

 

5

push back to release

3

 

drawer from runners

 

 

Push drawer runners back in.

13b REFIT THE DRAWER ONTO THE RUNNERS

(use 38 mm fixing screws & washers)

2

two pairs of formed

2brackets on either side of the chassis

(use 16 mm screws)

14b INTEGRATED MODELS WITH REMOTE (NZ AU) ONLY -

SECURE THE EXTERNAL VENT

 

 

 

the

release

tabs

 

 

 

 

 

 

 

 

mm

 

Pull

forward

100

Ensure the drawer is

 

sides

 

on

both

 

 

 

 

 

 

 

now rotated

 

 

 

 

 

 

 

 

 

 

 

 

 

clockwise back.

5

4

3

Before refitting the drawer, ensure the hoses are not twisted and the latches at the rear of each drawer runner are facing forward.

1

2

Ensure the release tabs on

1

both sides are reset fully.

 

2

After routing the vent hose through and out the hole cutout, attach and secure the vent by tightening the four screws provided.

Airflow

Image 17
Contents Installation Instructions DD90SDFHTX2 DD90SDFTM2 Follow the Installation Sequence Relevant to Your Model2b Additional Safety and Warnings Integrated Models only 2a Safety and Warnings ALL ModelsOptional 3a Parts Supplied ALL ModelsAttached to product 3b Additional Parts Supplied with Integrated ModelsPlan Product DimensionsCabinetry dimensions mm Cabinetry DimensionsFront Panel Specifications Min mm ventilation gap Water Connection 7a Cavity PreparationShelf cutouts Left hand side Maximum Distance of Hoses & Cord from Chassis EdgePage 9a Attach Side Mounting Brackets NOW Choose Which Installation Method a or b12a Secure the Drawer 11a Pull Through Hoses & Move Into the Cavity10b Pull Through Hoses & Move Into the Cavity 9b Integrated Models with Remote NZ AU only13b Refit the Drawer Onto the Runners 11b Remove the Drawer 12b Secure the Drawer to the CabinetryX14 17a Earth the Panel 18a Attach Panel to Product Badge zone When refitting Adjust Panel Height to Align the Cabinetry Gaps To required height Connect Inlet Hose to Cold Water 24 Plug ProductTroubleshooting Final Checklist