Whirlpool Systerm III manual General, Minimum%, Performance, Reduction, Contaminant, IlA, NSF Test

Page 12

PerformanceDataSheet

0 This product has been tested and listed by NSF International under NSFB Standard 42 for Taste, Odor and Chlorine reduction (Class I) and

Particulate reduction (Class II).

0 This product has been tested and listed by NSF International under Standard 42 NSFB for Taste, Odor and Chlorine reduction (Class I) and Particulate reduction (Class

II) and under Standard 53 for Cyst, Turbidity and Lead reduction.

Whirlpool Water Filtration System I

Whirlpool Water Filtration System II

Model No. WSClOOYW

Model No. WSCPOOYW

SPECIFICATIONS: Taste/Odor/Chlorine reduction (Class I) CAPACITY: 1,000 Gallons SERVICE FLOW RATE: 0.6 GPM (2.2 L/&n) @ 60 psi

SPECIFICATIONS: Lead and Taste/Odor/Chlorine reduction (Class I) CAPACITY: 500 Gallons

SERVICE FLOW RATE: 0.6 GPM (2.2 tJmin) @‘60 psi

General

Average

Maximum

Minimum%

NSF Test

 

Performance

lnfluent

Eff bent

Reduction

Requirement

 

Chlorine’

2.0

mg/L

co.1

mg/L

92%

minimum 75%

 

reduction

(Class

I)

 

 

 

 

 

 

 

Particulate

560,000

part/ml*

18,000

part/ml

98%

minimum 85%

 

reduction

(Class

II)

 

 

 

 

 

 

 

Perlotmance may very based on local water conditions.

 

 

 

 

 

‘Free

Available

Chlorine.

 

 

 

 

 

 

 

2Tesl

requirement

is at least 10,000 parlkl&mL

of AC Fine Test Dust.

 

 

r

 

 

 

 

 

 

 

 

 

 

General

 

 

Average

Maximum

Minimum%

 

NSF Test

 

Performance

 

 

lnfluent

 

 

Effluent

Reduction

 

Requirement

 

Chlorine’

 

 

 

2.0

mg/L

 

co.1

mg/L

 

92%

 

minimum7596

 

 

 

 

 

 

reduction

(Class

I)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Particulate

 

 

560,000

part/ml’

18,000

patVmL

98%

 

minimum 85%

 

 

 

reduction

(Class

II)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

cyst

 

215,000

4-6

p/ml3

390 4-6 gmL

 

99.9%

minimum

99.9%

 

 

 

 

 

reduction

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Turbidity

 

 

 

 

14 NTU

 

 

0.42

NTU

 

97%

minimum

effluent

 

 

 

 

 

 

 

 

 

1.O NTU

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Contaminant

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Reduction

 

U.i;lA

 

Average

Maximum

Minimum%

 

NSF Test

 

Performance4

 

 

 

 

 

lnfluent

 

Effluent

Reduction

 

Requirement

 

Lead

@ pH 6.5

0.015

mg/L

0.16

mgIL5

0.005

mg/L

97%

maximum

effluent

 

0.015

mg/L

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Lead

@ pH 8.5

0.015

mg/L

0.17

mg/mL5

0.002

mg/L

99%

maximum

effluent

 

0.015

mg/L

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

‘Free

Available

Chlorine.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Test

requirement

is

at

least

10,000

partiis/mL

of AC

Fins

Test Dust.

 

 

 

 

 

Test

rewiremet-

is

4-6

miuommer

size

~artidas

ger

mL of

influent.

 

 

 

 

 

 

‘These

&ntaminants

are not

necessarily

in your

n&r

supply.

Performance

may vary based on local

water conditions

 

5Tast

requirement

0.15

mg/L+

 

15%.

 

 

 

 

 

 

 

 

 

 

12

Image 12
Contents InstructionS Materials Needed for Basement Installation Materials Needed for Optional Sink Faucet InstallationSafety Glasses From Your Step ladder Additional TubingSystemsI,II Special care must be taken when drilling into Turnoff coldwatersupply.St la-lbPipeandstops.Stepslc-lg or 1h-lj Electrical Shock HazardYou are connecting the saddle valve to %6 to W Rigid metal or plastic pipe, skip ahead to hWater ConnectTo filtration assemblySteps.2d-2g 2b Connect system to refrigerator only 2d Connect system to optlonal sink faucetSide view of faucet 2h Connect systemTo refrigeratorStartUp GeneralInformation WaterRequirements Replacingfilter cartridgesPreparationfor longperiodsof non-use HowToArrangeForService If YouNeedAssistanceGeneral Minimum%Performance ReductionMaximum Lnfluent EffluentRequirement Whirlpool Corporation Benton Harbor. Ml