Cleveland Range OGB-6.20, OGS-6.20, OGS-10.10, OGB-10.10 manual Ladder Diagram

Page 100

A

B

12

/6.B5

/6.B5

 

A10:X15:11-

A10:X15:9-

FAN

 

 

3

4

5

6

7

8

A

/6.A6 -A10:X15:2

/6.B5

-A10:X15:8

B

C

D

E

LADDER DIAGRAM

LINE FILTER

RD

 

6

5

4

3

2

1

 

 

 

 

IRM

PTC

PTC W V

U

PE

SCH

 

 

 

 

 

 

X10:

 

GND

 

 

 

 

 

 

 

4

 

 

 

 

 

X12: TxD

 

3

 

 

 

 

 

 

RxD

 

2

 

 

 

 

 

 

12V

 

1

 

X11:

 

 

 

 

 

 

 

PE

N

L

 

 

 

 

 

 

 

3

2

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

15A

2A

1 GND

3RECIEVE

4TRANSMIT

12

N

90-264VAC

POWERSUPPLY 12VDC

GND

 

 

 

NEUTRAL

Hi-Limit

Hi-Limit

RESET AIR HEAT/GO

RESET AIR HEAT

PHASE ( L1 )

12 11 10 9 8 7 6 5 4 3 2 1

12

12VDC

0

L1

N

C

D

E

F

THIS DESIGN DESCRIBES A PROPRIETARY ITEM AND IS THE PROPERTY OF CLEVELAND RANGE. THIS DRAWING IS NOT TO BE COPIED OR USED WITHOUT THE APPROVAL OF CLEVELAND RANGE.

CLEVELAND RANGE, LLC

1333 East 179th St., Cleveland, Ohio 44110-2574

12

TITLE

WIRING DIAGRAM

OGS 6.20/10.10

3

4

VOLTAGE: 120VAC

WATTAGE: 10.25W

CURRENT: 11.7A

5

DRAWN BY

DRL

DRAWING NO.

300494

PRELIMINARY

 

REVA

DATE

8-9-05

SIZE

B

 

 

SHEET 5

OF 6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6

 

 

 

 

7

 

 

 

 

8

 

 

 

 

 

 

 

 

F

93

Image 100
Contents Service & Parts Manual Table of Contents Service Parts Maintenance For the Installer Cleveland Statement of Policies General Information about Combis Installation Instructions Installation of the Combi General Instructions Page Cleveland Range, LLC Advanced Closed System offers the following advantages GAS Fired Boilerless TOP View Model χ OGB-6.20 Saves energy Model χ OGS-6.20 Optional Plate Rack holds 42 plates Control Panel Basic Operation Control Panel Detail View Function Indicators AT the END of the DAY or Shift Avoid scratching the oven chamber or engaging frame Page Semi-Automatic Cleaning of the Oven Chamber Page CONVOClean Automatic Cleaning System optional Page Descale Steam Generator General Safety for Descaling Page GAS Generator W Cleaning Light Gasket C6015020 Condensate Box o-ring C6015000QTY Part N0 Description GAS INJ W Cleaning ASSY, Control PANEL, SPRITZER, with Picto GAS GEN W Cleaning ASSEMBLY/WELDMENT, Intermediate TOP, 6.20/10.20 Spray Handle Shut Off Valve C6014003 ASSEMBLY, Intake PLATE, Gas Component Panel ASSEMBLY, GAS OGB 6.20 & 10.10 ModelsPanel ASSEMBLY, Models GASOGS 6.20 & 10.10 Models ASSEMBLY, Control PANEL, with Picto ALL ModelsBASE, GAS Injector With Cleaning OGS 10.10 Models BASE, GAS Injector No Cleaning OGS 10.10 Models BASE, GAS Generator With Cleaning OGB 6.20 Models BASE, GAS GENERATOR, no Cleaning OGB 6.20 Models BASE, GAS Injector With Cleaning OGS 6.20 ModelsPage ASSEMBLY, Water Hose SYSTEM, Condenser ASSEMBLY, Water Valve ALL GAS 10.10 ModelsModels ASSEMBLY, Water VALVE, INJECTOR, GAS ASSEMBLY, Water SUPPLY, Generator W/CLEANING System OEB & OGB 6.20 ModelsALL GAS 6.20 Models Push Button SWITCH, INJ, CHANGE-OVER Contact ASSEMBLY, Steam GENERATOR, GAS OGB 6.20 ModelsPUMP, Steam GENERATOR, GAS ALL GAS ModelsASSEMBLY, Burner INSERT, Steam GENERATOR, NAT GAS Venturi 40 KWBurner INSERT, HL, PRE-MOUNTED ASSEMBLY, Burner INSERT, AIR, LP & NAT GAS Burner INSERT, HL, PRE-MOUNTED, 6.10/6.20Door 6.20 Complete OES 6.20 & 10.10 ModelsSliding PLATE, Complete ALL 6.20 &10.10 ModelsALL 6.20 & 10.10 Models Exterior Sheeting STAND, ASSEMBLY, Closed Base 10 & 10.10 ModelsPage Page Page Page ASSEMBLY, Stacking KIT, GAS Models 20 on 6.20 or 10 on 6.10 orASSEMBLY, Stacking KIT, Electric Models PIPE, Steam EXHAUST, ELECTRIC, Stacking KITCleveland Range OGB 6.20/10.10 Sequence of Operations Page Page Page Page Page Page Page Cleveland RANGE, LLC Wiring Diagram X12GND X23 X10 N20 N21 IVE Ladderdiagram Ladder DI RAM Cleveland Range OGS 6.20/10.10 Sequence of Operations Page Page Page Page Page OGS 6.20/10.10 Preliminary X39 A12 Preliminary Ladder Diagram Ladder