Cleveland Range OGS-10.10, OGB-6.20, OGS-6.20, OGB-10.10 manual Cleveland Range, LLC

Page 10
SECT. IIC PAGE 17 0406

SINCE 1922

INNOVATIVE STEAM COOKING SOLUTIONS

COMBI OVEN-STEAMER

 

 

Featuring the

 

 

"Advanced Closed

 

by

System +3"

 

 

GAS Fired – with Steam Generator

Cooking Modes:

 

Hot Air

Retherm

"Delta T" slow cooking

Steam

"Cook & Hold"

"Crisp & Tasty"

Combi

Cleveland Standard Features:

"Advanced closed system" with "Crisp & Tasty" de-moisturizing feature

High efficiency, power burner heating system for hot air and steam generator saves energy and provides fast heat up times

Fully insulated steam generator and cooking compartment for maximum energy savings

Polished cooking compartment with coved corners for easy cleaning

Three (3) 12" x 20" wire shelves

Hinged fan guard and hinged removable pan racks

Two (2) speed auto reversing convection fan for even heat distribution

Space saving, easy to close "Disappearing Door"

Door latch with safety vent position and wear-free door switch

Vented, double glass door with integrated door stop and self draining condensate drip pan

Easy to change, press-fit door seal

Oven light with shock resistant safety glass

Multipoint core temperature probe

Easy to use electronic controls for all operational functions

Self diagnostic system with full text message display

Easy to understand menu icons with bright graphics display

User friendly selector dial

Exclusive "Smart Key" for selecting option settings

Digital controls for temperature, time and core probe settings

Eight (8) "Press & Go" one step, recipe start buttons

Cook book library for up to 250 stored recipe programs, each recipe capable of 20 steps

RS 232 connection for controlling one unit with a PC (personal computer)

Memory module automatically saves unit settings and recipes

Manual program override feature for operational settings

Smooth action hand shower for compartment cleaning

Gas Fired Steam Generator

Quiet, high efficiency, power burner heating system

Built-in automatic rinse system

Automatic fill and water level control

Automatic generator drain

MODEL: χ OGB-10.10

CAPACITY: TEN (10) – 12" by 20" by 2 1/2" steam table pans

ITEM NUMBER __________________________________________

JOB NAME / NUMBER __________________________________

Short Form Specifications

Shall be Cleveland Model: OGB-10.10 Combination Convection Oven / Steamer with simple to operate electronic programmable controls for Hot Air, Convection Steam, and Combination cooking modes, "Cook & Hold" and "Delta T" slow-cooking capabilities, "Advanced Closed System" with "Crisp

&Tasty" de-moisturizing feature. Multiple cooking stage programs, stored recipe library, multipoint core temperature probe, "Press & Go", one-step recipe start buttons, "Smart Key" for selecting option settings, Two (2) speed auto reversing convection fan. Quiet, high efficiency power burner heating system; steam generator with automatic drain. "Disappearing Door". Capacity for ten (10) 12" x 20" x 2 1/2" pans.

Options and Accessories

ConvoClean automatic compartment washing system

PC-HACCP software for establishing "HACCP controls" and automatic documentation of the cooking process

Equipment stand(s)

Equipment stand(s) with Casters

Stacking kit for mounting one (1) OGB-6.10 model on top of one (1) OGB-10.10

Lockable cover over operating controls for prison installations

USB or RS 485 connection for networking and controlling up to 32 units with a personal computer

Propane gas option Flue diverter

Plate rack for banquet operations Plate rack cart

Thermal cover for plate or pan rack

ConvoClean compartment cleaning solution

ConvoCare concentrate for compartment rinse cycle "Dissolve" generator descaling solution

Chicken Grill Rack

12" x 20" Wire Baskets for frying products Additional 12" x 20" Wire Shelves

Cleveland Range, LLC

7

1333 East 179th St., Cleveland, Ohio, U.S.A. 44110

Ph: 1-216-481-4900 Fx: 1-216-481-3782 Web Site: www.clevelandrange.com

Image 10
Contents Service & Parts Manual Table of Contents Service Parts Maintenance For the Installer Cleveland Statement of Policies General Information about Combis Installation Instructions Installation of the Combi General Instructions Page Cleveland Range, LLC Advanced Closed System offers the following advantages GAS Fired Boilerless TOP View Model χ OGB-6.20 Saves energy Model χ OGS-6.20 Optional Plate Rack holds 42 plates Control Panel Basic Operation Control Panel Detail View Function Indicators AT the END of the DAY or Shift Avoid scratching the oven chamber or engaging frame Page Semi-Automatic Cleaning of the Oven Chamber Page CONVOClean Automatic Cleaning System optional Page Descale Steam Generator General Safety for Descaling Page GAS Generator W Cleaning Light Gasket C6015020 Condensate Box o-ring C6015000QTY Part N0 Description GAS INJ W Cleaning ASSY, Control PANEL, SPRITZER, with Picto GAS GEN W Cleaning ASSEMBLY/WELDMENT, Intermediate TOP, 6.20/10.20 Spray Handle Shut Off Valve C6014003 ASSEMBLY, Intake PLATE, Gas Component Panel ASSEMBLY, GAS OGB 6.20 & 10.10 ModelsPanel ASSEMBLY, Models GASOGS 6.20 & 10.10 Models ASSEMBLY, Control PANEL, with Picto ALL ModelsBASE, GAS Injector With Cleaning OGS 10.10 Models BASE, GAS Injector No Cleaning OGS 10.10 Models BASE, GAS Generator With Cleaning OGB 6.20 Models BASE, GAS GENERATOR, no Cleaning OGB 6.20 Models BASE, GAS Injector With Cleaning OGS 6.20 ModelsPage ASSEMBLY, Water Hose SYSTEM, Condenser ASSEMBLY, Water Valve ALL GAS 10.10 ModelsModels ASSEMBLY, Water VALVE, INJECTOR, GAS ASSEMBLY, Water SUPPLY, Generator W/CLEANING System OEB & OGB 6.20 ModelsALL GAS 6.20 Models Push Button SWITCH, INJ, CHANGE-OVER Contact ASSEMBLY, Steam GENERATOR, GAS OGB 6.20 ModelsPUMP, Steam GENERATOR, GAS ALL GAS ModelsASSEMBLY, Burner INSERT, Steam GENERATOR, NAT GAS Venturi 40 KWBurner INSERT, HL, PRE-MOUNTED ASSEMBLY, Burner INSERT, AIR, LP & NAT GAS Burner INSERT, HL, PRE-MOUNTED, 6.10/6.20Door 6.20 Complete OES 6.20 & 10.10 ModelsSliding PLATE, Complete ALL 6.20 &10.10 ModelsALL 6.20 & 10.10 Models Exterior Sheeting STAND, ASSEMBLY, Closed Base 10 & 10.10 ModelsPage Page Page Page ASSEMBLY, Stacking KIT, GAS Models 20 on 6.20 or 10 on 6.10 orASSEMBLY, Stacking KIT, Electric Models PIPE, Steam EXHAUST, ELECTRIC, Stacking KITCleveland Range OGB 6.20/10.10 Sequence of Operations Page Page Page Page Page Page Page Cleveland RANGE, LLC Wiring Diagram X12GND X23 X10 N20 N21 IVE Ladderdiagram Ladder DI RAM Cleveland Range OGS 6.20/10.10 Sequence of Operations Page Page Page Page Page OGS 6.20/10.10 Preliminary X39 A12 Preliminary Ladder Diagram Ladder